1. Home
  2. Resources
  3. RAM Concept tips
PT design guide  ·  Iron Axis engineering team

RAM Concept tips and tricks for PT slab design

Practical RAM Concept habits from our post-tension design and review work, plus the recurring problems and fixes discussed on Bentley’s RAM | STAAD forum and knowledge base, grouped by topic with a quick-fix table, FAQs and links to every source.

Design codes
ACI 318 · Eurocode 2 · PTI
Software
RAM Concept · AutoCAD · Revit

RAM Concept is a finite element program built around post-tensioned and reinforced concrete floors. It is quick to get a coloured plot out of it; it is less quick to get a model whose answers you would sign. Most of the problems we find when we review PT slab models are not software problems. They are input and interpretation problems: a support modelled with the wrong fixity, a design strip that misses part of the slab, a tendon profile that does not match the shop drawings.

This guide combines the habits our team applies on PT slab design and PT design review work with recurring questions answered by Bentley’s support engineers on the RAM | STAAD forum, the Bentley Communities knowledge base and the RAM Concept help. Bentley material is paraphrased in our own words and numbered references link to the original page in the sources list. Menus, defaults and limits change between versions, so check the help for the version you are using. For error messages, see our companion guide to RAM Concept errors and warnings; for long-term deflection, see RAM Concept load history deflection.

Jump to: Quick-fix table · Set-up · Meshing · Supports · Design strips · Tendons · Balance and precompression · Loads · Punching · Deflection · Vibration · RAM SS and CAD · Output · Speed and optimisation · Review order

Quick-fix table

Common RAM Concept symptoms, likely causes and fixes
SymptomLikely causeWhat to do
Mesh warnings every time you Calc AllObjects drawn without snapping, overlapping areas with the same priorityFix the reported coordinates on the Mesh Input plan; give thicker areas the higher priority[1]
Slab deflects inside a large column or thick wallColumns attach at one node; walls along their centrelineUse rigid support zones, or a stiff slab patch over the support[2] [3]
Two slabs at different levels behave as oneSlabs continuous in plan are connected whatever their elevationLeave a plan gap of at least about 75 mm (3 in), or use separate models[3]
“Reinforcing bar / tendon out of a cross section”Cross section trimming or slope limit removed the part the bar or tendon is inCheck the cross section perspective, then revise trimming, strips or bar position[4] [5]
Top bars run the full span after span detailingManual support widths with “Consider end as support” untickedTick both ends as supports, or let supports be detected[6]
Middle strip looks strong with no tendons in itBanded tendons miss the middle strip, so it carries hyperstatic axial force onlyUse full-width strips for PT, or distribute tendons so every strip is crossed[7] [8]
RC slab fails PT code provisionsSpan segments still set as post-tensionedUntick “Consider as Post-Tensioned” in the span properties[8]
Tendon perspective shows wrong elevationsProfiles are resolved only during Analyze All / Calc AllRun Analyze All after moving tendons or remeshing[9]
Punching plot shows “No Calc”Check misplaced after a column moved, or no valid critical section within the search radiusRe-place the check on the column; adjust search radius or edge treatment[10]
Stud rails not designed although “Design SSR if necessary” is tickedDemand above the code maximum shear strength, or rails reach the search radiusThicken, add a drop panel or column head, or raise concrete strength[10]
Pattern loading seems to change nothingStandard plots show the full pattern; envelopes sit elsewhereCheck max/min contexts and the Auditor for the enveloped design values[11]
Load history deflection gets worse with more bottom steelShrinkage warping, or a curvature sign change near contraflexureTest with shrinkage strain set to zero; see our load history guide[12] [13]
RAM Concept slow when opened through RAM Structural SystemFile embedded in the RAM SS working directoryUnlink the .cpt and work stand-alone where appropriate[14] [15]
DWG import throws an exceptionDrawing carries many unrelated objectsCopy only the floor plan into a clean drawing and import that[16]

1. Set up the model before drawing anything

  • Code and units first. Choose the design code (for example ACI 318-19, EN 1992-1-1 or BS 8110) and units at the start. Rule sets, default load factors, the creep and shrinkage model used for load history deflection, and the punching and deflection checks all follow from this choice[17].
  • Two concrete strengths. A PT slab needs the 28-day strength and the strength at stressing (transfer). Set both, and check the modulus of elasticity the program is using rather than relying on a default formula when the specification or test data give another value. The transfer strength is also used as the lower bound of the early-age modulus of rupture in load history calculations[17].
  • Strand and system data. Strand area, ultimate strength and modulus, plus the friction coefficient, wobble coefficient, anchor set and minimum vertical radius of the PT specialist contractor’s approved system. If the system is not yet known, record the assumed values in the calculation report so they can be checked later. See friction and wobble losses for typical ranges.
  • Clean drawing import. Import a cleaned DWG or DXF of the structural outline only: slab edges, columns, walls, openings and grids. Check units and origin before tracing. A drawing full of unrelated blocks, hatches and xrefs slows the model, causes snapping errors and can make the import fail; Bentley support’s fix for an import exception was to copy just the floor plan into a new file[16]. Delete the imported drawing when you no longer need it, because it adds to file size and speed[3].
  • Elevated slab or mat file. Both file types give the same capabilities; they are only set up with different default layers[3].

2. Mesh input and meshing

  • Snap everything. Bentley’s help states that nearly all meshing problems come from not using snapping properly. Slightly misaligned lines create slivers, “feature eliminated” and “recursion too deep” warnings, and pointy elements that distort contour plots[1].
  • Use priorities, not additive depths. Overlapping slab areas and beams need different priorities, and the thicker object should normally have the higher priority. Two overlapping objects with the same priority trigger a mesh error that gives the coordinates; turn on priority display in Visible Objects to find it[1] [3].
  • Minimum element size. The mesher works with a minimum element size of about 50 mm (2 in), which acts as a snap distance. Nodes closer than that are merged and reported as “line is too short”[1].
  • Element size. Bentley’s FAQ suggests roughly span/6 for a coarse preliminary mesh and span/12 for a fine final mesh, with a maximum element size of 10 m (32.8 ft). If in doubt, compare results at two mesh sizes[3].
  • Curved edges and circular drops. Model curves with a series of short straight segments, but not so short that the mesh becomes very fine locally[3].
  • Slabs at different levels. Slab areas that are continuous in plan are structurally connected in the model, even if their elevations do not overlap. To separate them, leave a plan gap; Bentley recommends at least 3 in (about 75 mm), because smaller gaps can disappear during meshing. Otherwise use separate models[3].
  • Copying supports above and below. To copy columns or walls below to above, copy, paste, then immediately change the pasted objects’ support set to Above. Abandoning the process after pasting leaves duplicate supports below, which causes errors[3] [1].
  • Regenerate the mesh after every geometry change, read the warnings, and look at the element plan before the analysis. RAM Concept remeshes on every Calc All while mesh errors remain[1].

3. Columns, walls and support stiffness

Columns and walls above and below the slab provide vertical support, rotational stiffness and, if you let them, lateral restraint. Each of these changes the answer.

  • Fixity and height. Set the height, section and near- and far-end fixity of each column and wall to match the frame. A pinned far end at a transfer level or above a raft is a different structure from a fixed one.
  • Lateral restraint. A column with a roller far end, or pinned at both ends, gives no lateral restraint to the slab. Columns above the slab do not support it vertically; they only add rotational and lateral restraint[3].
  • Walls and in-plane restraint. Walls restrain the slab laterally only when “Shear Wall” is ticked; otherwise the slab slides over the wall. Rotational stiffness about the wall’s axis is set separately with the fixity options[3]. Fully restraining a PT slab at stiff cores and long walls draws precompression into the walls in the analysis. We model the restraint we expect, and treat restraint shortening as a separate check; see shrinkage and creep in PT slabs and temperature and restraint cracking.
  • Point supports and rigid support zones. RAM Concept connects a column to the mesh at a single node at its centroid, and a wall along its centreline. The slab therefore deflects inside a large column or thick wall, which makes deflections and rotations conservative. From Version 8 Update 2 you can tick “Mesh Slab Support Region” in the column or wall properties so the mesh includes elements inside the support, stiffened by a factor (default and maximum 10). In older versions, a thick, high-priority slab patch over the column achieves a similar effect[2] [3].
  • Walls above the slab. A wall above has no restraint at its far end, even if “Rotationally Fixed at Far End” is ticked. If you model walls above as upturned beams instead, give them the no-torsion property, because thick slab elements overestimate torsional stiffness[3].
  • Loads from light walls above. One forum workflow places “dummy” walls above to locate line loads from light partition walls. Bentley’s advice was to keep a normal concrete unit weight, use a very small elastic modulus, and switch off self-weight of supports above in Calc Options, rather than using an unrealistic density[18].
  • Beams. The usual preference is to run beams through the column to the slab edge, matching how they are formed. Stopping a beam at the column centreline gives a slightly more flexible system[3].
  • Model drop panels, column heads and beams as slab areas with their own thickness, and set the priority so the thicker area wins where areas overlap.

4. Design strips, span segments and cross section trimming

RAM Concept designs reinforcement, checks stresses and reports most code checks on cross sections, not on individual elements. You define span segments in the latitude and longitude directions; the program generates design strips from them and cuts cross sections along each span. Anything not covered by a cross section is not designed.

  • Cover the whole slab in both directions. Gaps between strips leave areas with no reinforcement design, and they also make load history deflection unreliable, because those calculations use cross section results to adjust element stiffness[19] [20].
  • Full-width strips for PT. Column and half-middle strips change only how forces are integrated, not how load is distributed. Bentley’s technote explains that full-width column strips are typical for PT slabs because precompression is assumed to spread over the full tributary width and tendons are often banded on column lines. If a code requires column and middle strips, make sure tendons cross every strip[8].
  • Every strip needs a tendon. Strength design uses the tendons that cross each cross section. If banded tendons miss a half-middle strip, that strip receives hyperstatic axial compression alone and shows artificial bending strength; with no tension steel, the effective depth cannot be found, which upsets shear and ductility design[7].
  • Beams. Align the strip with the beam axis and use the Orient Span Cross-Section tool if the strip is slightly skewed. Set span ends at support centrelines. For beams supported on beams, untick automatic support detection and enter support widths manually; Bentley suggests making the width about 2 in (50 mm) larger than the actual support when the critical section is at the face, to avoid rounding and snapping issues. “Code T-Beam” width and the Beam design system are the usual settings[8].
  • Manual support widths and span detailing. With manual support widths, keep “Consider End 1 / End 2 as Support” ticked. If a support is not recognised at both ends, the span detailer runs top bars over the whole span. Shorter or longer detailed bars also change load history deflection, because only bars crossing a section count[6].
  • Middle strips with different support widths. Middle strips inherit the support width of their column strip. To use, for example, a zero support width for a full-width middle strip, draw those span segments manually[21] [8].
  • Reinforced, not post-tensioned. If a mild-steel slab fails PT provisions such as ACI 318 clause 18 checks, select all span segments on both span plans and untick “Consider as Post-Tensioned”[8].
  • Understand the shear core. One-way shear uses only the shear core, the vertical slices that run full depth through the trimmed section. In the cross section perspective, light blue is shear core, transparent parts count for flexure only, and black parts are ignored[4].
  • Choose trimming deliberately. Options include Max Rectangle, Slab Rectangle, Beam Rectangle, T or L, Inverted T or L, Max Shear Core and None. The inter cross section slope limit stops depth jumping between neighbouring sections; the manual recommends a maximum of 0.25, and Bentley notes many engineers use 0.5[4].
  • Drop caps and drop panels. RAM Concept does not distinguish them. A drop cap that does not meet drop panel dimensions should be trimmed out of flexure and one-way shear (slope limit 0 or Slab Rectangle), but its depth still counts in punching. Strips through drop panels need a section at the panel face, which the program adds automatically[4].
  • Stepped slabs. Where no trimming option suits a step, split the strip into two parts along the step[22]. If cranked top bars at a small step are flagged as out of section, ignoring them can be reasonable when they are in the compression zone; if they carry tension across the step, segment the span at the step[23].
  • Look at the cross sections in plan: they should cut across the full strip, not stop short at openings, and not capture a wall’s stiffness as slab. Read the span segment status; warnings about cross sections and classification usually point to a real input problem.

5. Tendon layout, profiles and losses

  • Layout. A common flat-slab arrangement is banded tendons on column lines in one direction and distributed tendons in the other. Latitude and longitude are only layer names; keep X tendons on one layer and Y on the other even if you use another arrangement[9]. Check average precompression and spacing limits of the governing code and PTI guidance, and keep tendons clear of openings and service zones.
  • Manual or generated tendons. Generated tendons come from banded tendon polylines, distributed tendon quadrilaterals and profile polylines on the Tendon Parameters layer. They follow slab-edge changes automatically, can be defined by strand count or effective force, and may extend past the slab edge. Manual tendons are edited one by one. You can use both, but never define the same tendons on both layers, or they are double counted[24].
  • Profile reference. “Above soffit” keeps a high point at a fixed height above the soffit if the slab thickens; “Top cover” or a negative “Above surface” keeps the strand at a fixed depth below the top, so a thicker slab gives more drape[9] [25].
  • High and low points at crossings. Set profiles from actual cover, chair heights and the order in which the two directions cross. At a crossing, one tendon sits on top of the other, so both cannot use the maximum eccentricity. Get this right in the model, or the shop drawings will not be buildable as analysed.
  • Half tendons. The inflection point is measured from the first point clicked, so draw half-span tendons starting from the high point to match full-span tendons. An inflection point ratio of 0.2 is a commonly used value[9] [25].
  • Strands per tendon. The total strand count must match the real structure, but the grouping into tendons does not have to. The exception is where a code deducts duct width from shear area; then model the real duct size and strands per duct[25].
  • Dropping strands. To reduce strands past a column, “fork” the tendon only when no jacks are modelled; with jacks, run a continuous tendon plus a separate shorter tendon alongside, because jacking tendons of different lengths gives wrong seating loss[9].
  • Effective or calculated force. Without jacks, RAM Concept uses the effective stress from the Materials criteria. With jacks it calculates friction (vertical curvature and plan kinks), seating and elongation, and the reported elongation already deducts seating. If any tendon on a layer has a jack, every tendon on that layer must have one[9] [26]. Either approach is valid; the shop drawings and stressing data must match the force the design relied on.
  • Minimum radius warnings. A radius warning on a parabolic tendon can indicate an over-balanced, over-draped profile. For deliberately harped tendons, create a separate PT system with zero minimum radius rather than ignoring the warning on every tendon[26].
  • “Inconsistent tendon half span ratios”. With generated tendons, make the profile polyline cross the banded tendon polyline exactly at its vertex. Bentley support described this warning as not critical[27].
  • Elevations and clashes. Tendon elevations in perspectives update only after Analyze All or Calc All. RAM Concept does not flag tendon clashes, so review the tendon perspective yourself[9].
  • Check the balance load as a proportion of self-weight, the precompression plot and the hyperstatic effects. A slab balancing well over its self-weight cambers upwards and can crack on top at stressing. See tendon profile and layout for the geometry.

6. Balance, hyperstatic loading and precompression

  • Balance equals primary plus hyperstatic. Balance loading is everything the tendons do to the slab including support restraint; primary is the unrestrained effect; hyperstatic is the difference[7].
  • Which goes where. Service combinations use the balance loading, because stresses come from P/A + M/S including restraint. Strength and ductility combinations include the hyperstatic loading and treat the tendon force as an internal force; never put balance loading in a strength combination, or the primary effect is counted twice[28] [7] [29]. ACI 318-19 (5.3.11) applies a load factor of 1.0 to secondary effects; see secondary moments.
  • Reading precompression plots. The Fx/Fy precompression plots come from the finite element axial forces, so force spreads from the anchorages according to element stiffness, not an assumed 45 degree angle. Small values outside the tendon zone come from restraint[30]. The centroid stress reported for a strip includes the precompression lost to support restraint[31].
  • Minimum average precompression. ACI 318 asks for at least 125 psi (0.9 MPa in ACI 318M) average precompression for two-way PT slabs. A Bentley engineer advised keeping a small margin above the limit, plotting the gross centroid stress next to the design status, and noting that plotted capacity lines are code limits, not your own limits. To change precompression, change the tendons (number or elevation) or the strips (width or trimming)[32]. See precompression limits and balanced load.

7. Loadings, patterns and load combinations

  • Keep loads on separate layers: self-weight, superimposed dead, partitions, live (reducible and unreducible), construction loads and transfer loads. It makes combinations transparent to a reviewer.
  • Self-weight. Slab self-weight is always included. Weight of columns and walls above is optional in Calc Options[33]. Check that superimposed dead load is not entered twice.
  • Overlapping surface loads add up in RAM Concept, unlike RAM Structural System where only the top one counts. Negative loads are allowed and can simplify load layouts. Non-uniform line loads take two comma-separated values; sloping surface loads take three[33].
  • Pattern loading is drawn, not automatic. You draw the load patterns graphically. The program then envelopes each pattern with the full pattern for design; standard plots show the full pattern, so look at max/min contexts or the Auditor to see the envelope[33] [11].
  • Live load reduction needs four things: a reduction code chosen in Calc Options (the default is None), reducible load types, a maximum reduction percentage above zero on the strips, sections, columns, walls or punching checks, and an elevated slab (no reduction on mats)[33].
  • “Rule set … load factors set for different purposes”. This warning appears when edited combinations no longer match the code defaults. If unintended, save, print the current combinations, use Criteria – Rebuild Load Combos and compare[33].
  • Check which rule sets (initial service, service, strength, ductility or minimum reinforcement, depending on code) are active for each combination. An inactive rule set gives a clean plot and no check.

8. Punching shear checks

  • Place a punching check at every column, including edge and corner columns and columns beside openings. RAM Concept states that its critical section selection is not infallible for unusual geometry, so review every section it draws[34].
  • Edge columns. A column centred on the slab edge gives awkward, skewed critical sections. Bentley’s advice in a forum case was to extend the slab to cover the column; for circular columns with drop caps, an equivalent square column simplified the check[35] [10].
  • Edge treatment and openings. “Sector voids” is always conservative but stops the critical section before it reaches a nearby slab edge; “failure planes” is probably more realistic at edges and corners but needs closer review[36]. For tiny openings near the column the two give almost the same answer; small openings far away can usually be left out of the punching model[10].
  • What the demand is. The program uses column reactions less point loads and column-above reactions inside the column shape; it does not deduct surface load inside the failure plane. Moments are taken about the critical section centroid, so edge and corner columns get moment even when pinned. Moments are elastic, not redistributed[10] [37].
  • Tendon component. With “Include tendon component in punch check reaction” ticked, tendon forces inside the column shape reduce the reaction; a tendon anchored inside the column eccentric to the failure plane can add significant moment[10]. Confirm whether a precompression contribution to resistance has been assumed and whether the column qualifies under your code.
  • Allowable stress already includes φ (for ACI, φ = 0.75 for shear)[10].
  • Stud rails, not cages. RAM Concept designs stud rails (including Ancon Shearfix) but not stirrup cages. One-way shear stirrups are not counted in punching, and studs are not counted in one-way shear[10].
  • No group punching and no wall punching. Each column is checked on its own; walls and pilasters in walls are not checked[10] [37].
  • Punching at beams. The program checks wherever you place a check. At deep beams, one-way shear in the beam is the likely mechanism; decide whether a punching check is meaningful[37].
  • Carry stud layouts through to the drawings and check they fit with tendons and anchorages at the column. See punching shear in PT slabs.

9. Deflection: elastic plots versus load history

  • Deflection contour plots show a linear elastic analysis with the combination’s standard factors. Cracking, creep, shrinkage and load sequence come only from the separate Calc Load History Deflections command, which needs load history steps defined[38].
  • Load history results ignore load patterns, live load reduction and alternate load factors, and dynamic effects are not considered[38].
  • Include the balance loading in every load history combination for PT slabs; leaving it out removes precompression and causes equilibrium or convergence problems[39].
  • The full workflow, calc options, convergence fixes and the “unexpected” results discussed on the forum are in our guide to RAM Concept load history deflection. For code background see long-term deflection: Eurocode 2 vs ACI 318.

10. Vibration analysis

  • Walking frequency range. RAM Concept would not accept a minimum footstep frequency of 0.83 Hz in one forum case. Bentley’s view was that very slow walking is unlikely to cause a resonant response in concrete floors and a 1 Hz minimum loses little[40].
  • Weight of person. The default is 200 lb (about 890 N), while many references, including AISC Design Guide 11, use about 157 lb (700 N). Bentley suggested choosing a weight with a probability of exceedance consistent with the dynamic load factors used (about 25%)[41]. State the value in the report.
  • Stiffness for vibration. Calc Options lets the vibration analysis use gross properties with any stiffness modifiers, or stiffness from a load history step (cracked). Bentley recommends gross properties with no modifiers before running load history, because load history already accounts for cracking. A too-high excitation response threshold factor can make the analysis appear to do nothing[40].
  • See PT slab floor vibration for footfall criteria and when the check matters.

11. RAM Structural System integration and CAD

  • What comes across. Concrete slabs, beams, columns, walls, openings, sizes, materials, column fixity and loads are imported. Steel members, composite flat slabs, snow loads and steel-beam reactions are not. Sloped slabs come in flat, beams are assumed fully fixed, and wall fixity is always pinned near and far, so review supports after import[42].
  • Transfer loads. A green model status light in RAM SS is needed for transfer reactions to import; reducible transfer loads on elevated slabs come in unreduced[42].
  • Wind loads in older RAM SS versions came in as service loads even when ASCE 7-10 wind is ultimate; change the loading type and rebuild combinations if that applies[42].
  • Openings across walls. Side-by-side RAM SS openings merged across a wall leave no slab along the wall, giving mesh errors and an unstable wall. Add a sliver of slab or a beam along the wall in RAM Concept, or model two separate openings in RAM SS[43].
  • Partial levels that do not include all concrete columns drop those columns from the Concept model[43]. Loads placed inside openings are ignored with a warning[43].
  • Mats with walls crossing two foundations can import duplicate walls; segment the wall at the boundary or use one mat with openings[44].
  • Slow when opened through RAM SS. The embedded file runs from the RAM SS working directory; pulling it out and working stand-alone is a valid option. Bentley documents how to copy the .cpt###E file from the working folder and rename it to .cpt[14] [15]. When re-syncing, untick slabs, beams and openings you have edited in RAM Concept[15].

12. Plans, reports and drawing export

  • A plan exports exactly what is visible, as DWG or DXF in older AutoCAD formats (R12 to 2004 in the current help), and tables export as text[45].
  • Set the print area and print scale per plan, ticking “Set for all plans” for reports. Plans and layers are only included in the full report when their Include flag is Yes[46].
  • Create custom plans for the results you need (Layers – New plan), and use the min and max frame numbers to show a single design strip or only the column strip[46].
  • If a perspective shows nothing, zoom to extents or show the print viewpoint; cross sections only exist after Calc All[46]. To select one of two coincident objects, double-click with snaps off[46].

13. Speed, file size and PT optimisation

  • To speed up a slow model: increase element size, delete imported drawings you no longer need, reduce load cases and combinations, and reduce strips or widen cross section spacing[3]. Use Process – Analyze All when you only need analysis results, not design[9].
  • A strip can be given zero cross sections (minimum divisions 0 with a large spacing) so it shapes neighbouring strips without adding calculation time[21].
  • PT design optimisation changes strand counts and profile elevations only, not tendon positions in plan, so start from a sensible layout using generated tendons. Bentley recommends at most about 50 optimisable properties per optimisation region (75 is the limit), regions that match likely pours, and keeping support high points fixed at maximum except over cantilevers[47]. We treat optimiser output as a starting point; see PT design optimisation.

14. Reviewing results in a sensible order

  1. Equilibrium. Compare total reactions with a hand calculation of the total load for each load layer.
  2. Deflected shape. Look at the shape before the numbers. Unexpected local dishing usually means a missing support or a modelling error.
  3. Balance and precompression. Balance load ratio, precompression range and the effect of restraint.
  4. Stresses. Transfer and service stresses against the code limits for the slab classification. See transfer and service stress checks.
  5. Reinforcement. Design status, required reinforcement and whether it is practical to detail.
  6. Punching. Ratios at every column, with the critical sections reviewed.
  7. Deflection and vibration. Load history deflection or justified multipliers, and a footfall check where spans or occupancy call for it.

Common errors we find in RAM Concept reviews

Frequent model issues and what they cause
IssueConsequence
Concrete strength at stressing missing or too highTransfer stresses and anchorage checks look better than they are
Design strips leave areas of slab uncoveredNo reinforcement designed there; deflection results unreliable
Tendon profiles do not match the shop drawingsBalance load, stresses and strength differ from what is built
Hyperstatic effects left out of strength combinations, or balance includedReinforcement over supports or in spans under- or over-designed
Wrong column or wall fixity, or full in-plane restraintMoments, precompression and punching forces redistributed incorrectly
Deflection checked only on the linear elastic plotLong-term deflection with cracking, creep and shrinkage underestimated
Openings added after the strips and tendons were laid outTendons through openings; cross sections and punching perimeters wrong

Finally, compare the model with the drawings: tendon numbers, profiles, anchor positions, slab thickness and openings. Our in-house tools help with this step by reading the model and drawing data directly, but the engineering judgement on whether the results make sense remains ours.

Talk to us about your RAM Concept model. We design PT slabs in RAM Concept and review models prepared by others. Send us the model and drawings for a PT design review or a PT design optimisation, ask about a full post-tension design package, read about our post-tension design in the UAE, or contact our engineers.

Related PT design guides: RAM Concept errors and warnings, RAM Concept load history deflection, ultimate strength and secondary moments, punching shear in PT slabs, PT design review checklist.

Sources

Bentley Systems pages consulted on 13 November 2026. Content is paraphrased in our own words; RAM Concept is a Bentley Systems product and this guide is not Bentley documentation. Forum answers describe the software at the time they were written, so check behaviour in your version.

  1. RAM Concept help: Errors and warnings: Meshing
  2. Bentley Communities wiki: Rigid Support Zones in RAM Concept
  3. Bentley Communities wiki: RAM Concept Modeling and Meshing [FAQ]
  4. Bentley Communities wiki: Cross Section Trimming [TN]
  5. Bentley Communities wiki: RAM Concept - Reinforcing bar out of cross section
  6. RAM | STAAD Forum: RAM Concept span detailing
  7. Bentley Communities wiki: Balance and Hyperstatic Loading [TN]
  8. Bentley Communities wiki: RAM Concept Design Strips [TN]
  9. Bentley Communities wiki: RAM Concept Tendons [FAQ]
  10. Bentley Communities wiki: RAM Concept Punching Shear Checks [FAQ]
  11. RAM | STAAD Forum: Issues with pattern loading in RAM Concept
  12. Bentley Communities wiki: Ram Concept Load History Deflections Unexpected Behavior
  13. RAM | STAAD Forum: Load History Deflections - RAM Concept
  14. RAM | STAAD Forum: Performance when running RAM Concept opened from Structural System
  15. Bentley Communities wiki: Unlinking Ram Concept Files from RAM SS
  16. RAM | STAAD Forum: "External component has thrown an exception" in RAM Concept
  17. Bentley Communities wiki: RAM Concept Load History Calc Options [TN]
  18. RAM | STAAD Forum: RAM Concept - Dummy Walls Above Slab
  19. RAM Concept help: Errors and warnings: Load History Deflections
  20. RAM Concept help: Advice on drawing cross sections
  21. RAM Concept help: Design strips: miscellaneous tips
  22. RAM | STAAD Forum: RAM Concept - design strips - cross section trimming
  23. RAM | STAAD Forum: RAM Concept - Reinforcing bar out of cross section
  24. Bentley Communities wiki: Automated Tendon Generation in RAM Concept
  25. RAM Concept help: Tendon properties
  26. RAM Concept help: Errors and warnings: Tendons
  27. RAM | STAAD Forum: Inconsistent tendon half span ratios
  28. RAM Concept help: Tendons: external load or internal force?
  29. RAM | STAAD Forum: Hyperstatic Loads vs Balance Loads
  30. RAM | STAAD Forum: P/A calculation - RAM Concept
  31. RAM | STAAD Forum: RAM Concept: Precompression values on Design Strips
  32. RAM | STAAD Forum: Precompression Failure
  33. Bentley Communities wiki: RAM Concept Loading [FAQ]
  34. RAM Concept help: About punching shear checks
  35. RAM | STAAD Forum: RAM Concept Shear Studs Design
  36. RAM Concept help: Punching shear check properties: General
  37. RAM Concept help: Frequently asked questions: Punching Shear
  38. RAM Concept help: About RAM Concept's load history deflection calculations
  39. Bentley Communities wiki: RAM Concept - Load History Convergence
  40. RAM | STAAD Forum: RAM Concept Vibration Analysis - Calc Options
  41. RAM | STAAD Forum: Ram Concept Vibration Analysis - Weight of Person
  42. Bentley Communities wiki: Importing Items into RAM Concept
  43. Bentley Communities wiki: Common Errors and Warnings When Importing into RAM Concept [TN]
  44. RAM | STAAD Forum: Analysis Error - Two wall elements above the slab are at the same location
  45. RAM Concept help: Exporting Plans and Tables
  46. Bentley Communities wiki: RAM Concept Plans And Printing [FAQ]
  47. Bentley Communities wiki: General Workflow for RAM Concept PT Optimization

Part of our PT design guides. RAM Concept and RAM Structural System are products of Bentley Systems; menu names, defaults and limits vary between versions, so confirm them in the help for your version. Codes are referred to by clause where we are confident of the reference; always check the edition and national annex adopted for your project.

S-210 FAQ

Questions we are asked about this.

What is the difference between design strips and span segments in RAM Concept?

Span segments are drawn (or generated) between supports in each direction. RAM Concept generates design strips from them and cuts cross sections along each span, where it integrates forces and designs reinforcement and checks stresses. Areas not covered by a cross section are not designed, and load history deflection also relies on that coverage.

Should PT slabs in RAM Concept use full-width strips or column and middle strips?

Bentley’s design strip technote notes that full-width column strips are typical for post-tensioned slabs, because precompression is assumed to act over the full tributary width and tendons are often banded on column lines. If your code requires column and middle strips, make sure tendons cross every strip, otherwise a strip with no tendon receives hyperstatic axial force only and its strength is misrepresented.

Should balance or hyperstatic loading go in RAM Concept strength combinations?

Hyperstatic. Service combinations use the balance loading; strength and ductility combinations include the hyperstatic loading and treat the tendon force as an internal force. Adding balance loading to a strength combination counts the primary prestress effect twice.

Why does my RAM Concept slab deflect inside a large column?

Columns attach to the mesh at a single node and walls along their centreline, so the slab can deflect between the node and the support face. From Version 8 Update 2 you can mesh the slab support region with a stiffness factor; in older versions, a stiff, high-priority slab patch over the column gives a similar effect.

Should I use effective force or calculated force for tendons in RAM Concept?

Both are valid. Without jacks the program uses the effective stress set in the Materials criteria; with jacks it calculates friction, seating and elongation along each tendon. What matters is that the shop drawings and stressing data match the force the design relied on.

Why are no stud rails designed when the punching check fails in RAM Concept?

Stud rails are extended up to the punching check search radius. If the check still fails there, or if the demand exceeds the code’s maximum nominal shear strength, no rails are designed. The slab, drop panel or concrete strength needs to change.

Does RAM Concept check punching at walls or for groups of columns?

No. Each column reaction is checked on its own and walls are not checked for punching, so closely spaced columns and wall ends need separate engineering checks.

Can you review a RAM Concept model prepared by another engineer?

Yes. Our PT design review covers model inputs, supports, strips, tendons, load combinations, punching checks, deflection and results, and we report findings with references to the governing code.

S-901 Contact

Send the drawings. Get an answer from our engineers.

WhatsApp or email the architectural or structural set, the location and what you need. The reply comes from the engineers who will do the work, with a proposed scope and programme.

Office
Al Warqa 1, Dubai, UAE
Hours
Sunday – Thursday, 09:00 – 18:00 GST