RAM Concept load history deflection: set-up, calc options and troubleshooting
How RAM Concept’s load history deflection works, how we set up load steps and calc options on PT slabs, and the convergence problems and surprising results Bentley’s engineers have explained on the forum and knowledge base.
Long-term deflection often governs thin PT and RC flat slabs, and it is where RAM Concept models are most often misread. The coloured deflection plot you get after Calc All is a linear elastic result. Cracking, creep, shrinkage and load sequence only enter through the separate load history calculation. This guide sets out how that calculation works, the settings we check on every model, and the problems discussed by Bentley’s engineers on the RAM | STAAD forum and knowledge base. Bentley material is paraphrased, with numbered references to the original pages in the sources list. For code background, see long-term deflection: Eurocode 2 vs ACI 318; for general modelling, our RAM Concept tips and tricks.
1. How the calculation works
- The global analysis stays linear elastic. Load history calculations work on the design strip cross sections, including cracking, creep, shrinkage, tension stiffening and load sequence, and use the results to modify element stiffness in the global model[1].
- For each step, RAM Concept solves section forces, calculates gross, uncracked, cracked and creep curvatures, averages them with the tension stiffening model, sets element stiffness factors, re-analyses and repeats until the deflection change at a key node converges[2].
- Once a cross section cracks it stays cracked for later iterations and steps, and forces redistribute from cracked to less-cracked regions[3].
- The calculation uses the PCA concrete stress-strain curve, adjusts the modulus of rupture for early-age loading, and models internal shrinkage restraint from reinforcement rigorously[4].
- Tension stiffening uses the Eurocode 2 approach with β = 0.5 (sustained loading) for every step, because research shows tension stiffening decays within weeks. Cracking uses the flexural tensile strength (for Eurocode, fctm,fl). Creep strain is carried forward between steps and none of it is treated as recoverable[5] [4].
- All reinforcement and tendons crossing the cross sections count, top and bottom, user and program bars, including development length[5] [6].
- Patterns, live load reduction and alternate load factors are not considered, nor are dynamic effects[1].
2. Cross sections decide the answer
- Every element with significant force must lie within a cross section tributary in two directions. If coverage looks low, RAM Concept warns you; the warning is acceptable only in one-way regions whose span direction is covered[7].
- In crack-sensitive slabs, especially RC, avoid very wide cross sections where moment changes steeply: averaging hides peak stresses, under-predicts cracking and so under-predicts deflection. Column and middle strips help here[8].
- For T-beams, do not split web and flange into separate cross sections; the bending carried as eccentric axial force is not captured by the curvature-based stiffness adjustment. Use a reasonable effective flange, for example “Code T-beam” width[8].
- When drawing design sections by hand, check their tributary length so elements are covered[8].
3. Setting up load history steps
- Each step is a load combination applied for a duration; zero duration means instantaneous. Steps are solved in sequence, each carrying the effects of the previous ones[1].
- Base the initial load application on the real stripping and back-propping schedule. Bentley notes that in the USA formwork is often removed after 3 to 7 days; one forum user correctly entered 85 days because formwork stayed in place that long[9] [10]. In the UAE and KSA we take the date from the contractor’s programme and state it in the report.
- For PT slabs, include dead load and the balance loading in every combination used in the load history. Without balance loading, precompression disappears and equilibrium or convergence problems follow[2] [11].
- Combinations used only for load history do not need a design rule set[5].
- Check the sustained live load fraction in your sustained combination. Bentley pointed out that for some codes the default sustained combination uses 50% of live load, not the 25% a user expected[12].
- Add extra steps at any age you need results for, for example at finishes installation and at end of service life. At the time of a Bentley forum answer, a new step could not be inserted at the start of an existing sequence, so plan the order before entering steps[1] [5].
| Step | Combination | Duration |
|---|---|---|
| Stripping / back-props removed | Self-weight + balance (+ construction load if relevant) | Until finishes are installed |
| Finishes and partitions installed | Dead + superimposed dead + balance | Short or instantaneous |
| Sustained service | Dead + superimposed dead + sustained live + balance | Long term, e.g. several years |
| Final instantaneous | Full service load + balance | 0 days |
4. Calc options worth checking
- Creep and shrinkage model. From Version 8 Update 2, RAM Concept offers ACI 209.2R-08 (GL2000), AS 3600-2018, Eurocode 2-2004 and ACI 209R-92 (ECR values). New models default to GL2000 for ACI 318, CSA and IS 456, and to Eurocode 2-2004 for Eurocode and BS 8110 codes. Older models opened in newer versions keep ACI 209R-92[9]. Check which one your model is using.
- “Code” values. Bentley recommends leaving the basic creep coefficient and shrinkage strain on “Code”, but notes that defaults for humidity and similar parameters are not endorsed for every project or region[9]. Gulf humidity and curing conditions deserve a deliberate choice.
- Ageing coefficient can normally be taken as 0.8[9].
- External shrinkage restraint. This approximates cracking from stiff supports restraining shrinkage. Before Version 8 Update 2 new models defaulted to 20%; since then the default is None (0%), which Bentley considers may suit a typical intermediate floor of a multi-storey building. Higher values may be appropriate for podiums, transfer plates, basement slabs and floors on stiff foundations[9] [13].
- Do not double count restraint. Because RAM Concept already models internal restraint from reinforcement, Bentley advises against also using a reduced modulus of rupture or reduced cracking moment, which are hand-method approximations of the same effect[9].
5. Reading the results
- Results are stored per step in the load history folder and represent the state at the end of each step[1].
- For long-term sustained plus full live deflection, read the final instantaneous step; it already includes the creep, shrinkage and cracking history, so do not add earlier results by hand[12].
- Use difference (“diff”) plots between steps for the incremental deflection after partitions are installed, which is what ACI’s limits for attached non-structural elements address[3] [12].
- The fa/fcr plot shows where sections are treated as cracked (values of 1 or more); an unrestrained fa/fcr plot excludes the shrinkage restraint percentage[1] [5].
- From Version 8 Update 2 the load history results tables list fa/fcr, Ieff/Ig, modulus of rupture and other values per section and step, which helps trace an unexpected result[14].
- Treat every prediction as an estimate. Bentley’s help warns that aggressive, thin designs need a thorough understanding of the method and that poor bar placement and vibration are not covered[1].
6. Troubleshooting from the forum
| Problem | Explanation | What to try |
|---|---|---|
| Solution does not converge | Often runaway cracking, sections without equilibrium, or steps missing dead or balance load | Read the load history calc log, check first-order service deflection, remove any pre-cracked stiffness from mesh input, include balance load, add user reinforcement where cracking runs away[11] [2] |
| Adding bottom bars increases deflection | Shrinkage warping: steel on one face restrains shrinkage there and curves the section | Run with shrinkage strain set to zero to isolate the effect[15] |
| PT beam deflects more with extra user bars | A curvature sign change between iterations near contraflexure reduced element stiffness; force transformation from temperature tendons in the middle strip | Untick “Design Column Strip for Column + Middle Strip Resultants” for that span segment, as Bentley suggested[16] |
| Bigger columns give bigger deflection | The first section moves to the face of a large column, past the inflection point, and cracks; point supports exaggerate this | Model a stiff slab region over each column (custom behaviour, stiffness factors 10) or use rigid support zones[15] [17] |
| Deflection changes after span detailing | Detailed bar lengths change which sections each bar crosses | Check support recognition and bar run-outs, then re-run[6] |
| Load history differs from strip long-term deflection plot | Bentley’s help notes the two use entirely different methods | Where deflection governs, we rely on the load history result and treat the strip plot as a quick estimate[18] |
7. Our checklist before we sign off a deflection result
- Design strips and sections cover the slab in both directions, with sensible widths.
- Supports, including rigid support zones over large columns, are modelled as intended.
- Steps follow the construction programme; balance load is in every PT step.
- Creep and shrinkage model, humidity, cure duration and shrinkage restraint are chosen and stated.
- Calc log reviewed; no convergence or coverage warnings left unexplained.
- Incremental and total deflections compared with project limits, with a hand estimate as a sanity check.
Need a second opinion on slab deflection? We run and review RAM Concept load history analyses for PT and RC floors. Send us the model for a PT design review or ask about PT design optimisation, or contact our engineers.
Related PT design guides: RAM Concept tips and tricks, RAM Concept errors and warnings, long-term deflection: Eurocode 2 vs ACI 318, shrinkage and creep in PT slabs.
Sources
Bentley Systems pages consulted on 13 November 2026. Content is paraphrased in our own words; RAM Concept is a Bentley Systems product and this guide is not Bentley documentation. Forum answers describe the software at the time they were written, so check behaviour in your version.
- RAM Concept help: About RAM Concept's load history deflection calculations
- Bentley Communities wiki: RAM Concept - Load History Convergence
- Bentley Communities wiki: RAM Concept Load History Deflections and ACI Deflection Limits
- Bentley Communities wiki: RAM Concept Load History Deflection Calculations
- RAM | STAAD Forum: RAM Concept Questions on Load History analysis
- RAM | STAAD Forum: RAM Concept span detailing
- RAM Concept help: Errors and warnings: Load History Deflections
- RAM Concept help: Advice on drawing cross sections
- Bentley Communities wiki: RAM Concept Load History Calc Options [TN]
- RAM | STAAD Forum: RAM Concept - Reinforcing bar out of cross section
- RAM | STAAD Forum: RAM Concept - Load History Deflections Not Converging
- RAM | STAAD Forum: Understanding Load History Deflection for Long Term and Incremental
- Bentley Communities wiki: External Shrinkage Restraint for Multi-Story Concrete Structures
- Bentley Communities wiki: RAM Concept Load History Deflection Analysis Results Table
- Bentley Communities wiki: Ram Concept Load History Deflections Unexpected Behavior
- RAM | STAAD Forum: Load History Deflections - RAM Concept
- Bentley Communities wiki: Rigid Support Zones in RAM Concept
- RAM Concept help: Why are load history deflection results different from Long Term Deflection results plotted for the strip?
Part of our PT design guides. RAM Concept and RAM Structural System are products of Bentley Systems; menu names, defaults and limits vary between versions, so confirm them in the help for your version. Codes are referred to by clause where we are confident of the reference; always check the edition and national annex adopted for your project.
Questions we are asked about this.
Is the RAM Concept deflection plot a long-term deflection?
No. The standard deflection plots are linear elastic results for each combination. Long-term deflection including cracking, creep and shrinkage comes only from the separate load history calculation, run after load history steps are defined.
Which step gives long-term deflection in RAM Concept?
The last step, usually a zero-duration final instantaneous step with full service load. It already contains the creep, shrinkage and cracking history from earlier steps. Use difference plots between steps for incremental deflection after partitions are installed.
What shrinkage restraint percentage should I use in RAM Concept?
Since Version 8 Update 2 the default is None (0%), which Bentley considers may suit a typical intermediate floor of a multi-storey building. Podiums, transfer plates, basement slabs and floors on stiff foundations may justify a higher value. It is an engineering choice to state in the calculations.
Why did my RAM Concept deflection increase when I added reinforcement?
Often shrinkage warping: reinforcement on one face restrains shrinkage on that face and induces curvature. Bentley suggests running with shrinkage strain set to zero to isolate the effect. Near contraflexure, a curvature sign change between iterations can also reduce element stiffness.
Does RAM Concept load history include pattern loading or live load reduction?
No. Load history calculations do not consider load patterns, live load reduction or alternate load factors, and dynamic effects are not included.
Technical information only. This article is general engineering information to help you understand the subject. It is not design advice for a specific project, codes and authority requirements change, and worked examples are illustrative. Designs must be prepared and checked by a qualified structural engineer responsible for the project, to the code edition adopted for the project. Disclaimer · Terms of use.
Send the drawings. Get an answer from our engineers.
WhatsApp or email the architectural or structural set, the location and what you need. The reply comes from the engineers who will do the work, with a proposed scope and programme.
- +971 52 118 2569
- Telephone
- +971 52 118 2569
- Office
- Al Warqa 1, Dubai, UAE
- Hours
- Sunday – Thursday, 09:00 – 18:00 GST