Free tool  ·  Indicative  ·  Iron Axis engineering team

PT long-term prestress loss calculator

Estimate long-term prestress losses in post-tensioned slabs and beams to ACI 318 (Zia et al. method) or Eurocode 2 (eq. 5.46), for 12.7 mm and 15.2 mm strand. Creep, shrinkage, relaxation, elastic shortening, friction and draw-in, with the full working, a printable report, a PDF and a CSV. Every result is indicative.

Engineering disclaimer. This free tool is for preliminary checks and education only. It uses simplified code methods and your inputs, and it is not a substitute for project design. Results must be verified by a qualified structural engineer responsible for the project. Verify every result against the current code edition, national annex, authority requirements and the project drawings before use. Iron Axis accepts no liability for decisions or designs based on these results. Read the full disclaimer.
Code and strand
Strands in the section width below.
fpu = 1,860 MPa. ACI 318 limit 0.80 fpu; EC2 recommends min(0.80 fpk, 0.90 fp0,1k).
Use the mill certificate value when known.
Concrete and section
1,000 mm gives results per metre of slab.
Below the centroid is positive. Use 0 for the average precompression of an unbonded slab.
At the section, over width b. Only used when e ≠ 0.
Superimposed dead load plus quasi-permanent live load (ψ2 Q).
Environment and ages
Air-conditioned interiors are often 40 to 60%.
50 years or more gives final values.
0.5 for many tendons stressed in sequence; 0 for a single tendon.
Friction and draw-in (short-term)
Sum of angle changes over L.
Use the approved PT system values.
Comparison
Only used for the comparison note.
— MPa effective stress fse ACI / Zia et al.
Step-by-step working

Indicative only, not a design. The results follow simplified code methods and depend on your inputs. Verify losses with the project design, the approved PT system data, the strand certificates and the code edition and national annex adopted for the project.

How we calculate

1. Strand, jacking stress and code limits

  • Strand: 12.7 mm (0.5 in, Ap = 98.7 mm²) or 15.2 mm (0.6 in, Ap = 140 mm²), Grade 270 low-relaxation strand with fpu = 1,860 MPa [7]. The nearest Eurocode sizes, Y1860S7 12.9 mm (100 mm²) and 15.7 mm (150 mm²) [6], have slightly larger areas; scale the forces if you use them.
  • fpj = (jacking ratio) × fpu. We check it against ACI 318-19 Table 20.3.2.5.1, min(0.94 fpy, 0.80 fpu) with fpy = 0.90 fpu [1], or EN 1992-1-1 5.10.2.1, min(0.80 fpk, 0.90 fp0,1k) with fp0,1k taken as 0.88 fpk [5]. We also flag an anchorage stress after lock-off above 0.74 fpu for ACI.

2. Friction, wobble and draw-in (optional)

  • σ(x) = fpj e−(μθx/L + Kx), with the angle change θ taken as accumulating evenly along a tendon stressed from one end [4].
  • Draw-in: after lock-off the stress follows reverse friction, σa(x) = σ(xset)²/σ(x), and xset is found so that ∫[σ(x) − σa(x)]dx = Epδ. If xset would exceed L, the whole tendon is shifted.
  • Initial stress fpi is the average stress along the tendon for unbonded tendons, or the stress at the section x for bonded tendons.

3. ACI 318: Zia et al. (1979) method

ACI 318-19 requires the losses from elastic shortening, creep, shrinkage and relaxation to be accounted for [1]. ACI 423.10R describes the available methods [2]; we use the component method of Zia et al. [3], in SI units:

  • Moduli: Ec = 4,700√fc′ and Eci = 4,700√fci′ (normalweight concrete) [1].
  • Concrete stress at the tendon: fcir = Pi/Ac + Pie²/Ic − Mge/Ic, and fcds = Msde/Ic, gross section. With e = 0 this is the average precompression used for unbonded tendons.
  • Elastic shortening: ES = Kes(Ep/Eci)fcir, Kes = 0.5 for tendons stressed in sequence [3].
  • Creep: CR = Kcr(Ep/Ec)(fcir − fcds), Kcr = 1.6 for post-tensioned members [3].
  • Shrinkage: SH = 8.2×10⁻⁶ KshEp(1 − 0.06 V/S)(100 − RH), V/S in inches (h/2 with two faces drying, h with one). Ksh follows the Zia table for post-tensioned members by days from the end of moist curing to stressing (1.0 if stressed at the end of curing, 0.92 at 1 day, 0.77 at 7 days, down to 0.45 at 60 days) [3].
  • Relaxation: RE = [Kre − J(SH + CR + ES)]C, with Kre = 34.5 MPa (5,000 psi) and J = 0.040 for low-relaxation Grade 270 strand, and C from the Zia table at fpi/fpu (0.75 at 0.70, 1.00 at 0.75, 1.28 at 0.80) [3].
  • The method gives final (long-term) values, so the age considered is not used in the ACI option.

4. Eurocode 2: EN 1992-1-1 eq. 5.46

  • fcm = fck + 8, Ecm = 22(fcm/10)0.3 GPa, fcm(t0) = βcc(t0)fcm with s = 0.38, 0.25 or 0.20 for cement class S, N or R, and Ecm(t0) = (fcm(t0)/fcm)0.3Ecm [5].
  • Elastic shortening (5.10.5.1): Δσel = j(Ep/Ecm(t0))σc, with j ≈ 0.5 for sequential stressing [5].
  • Creep coefficient (Annex B): φ(t,t0) = φRHβ(fcm)β(t0)βc(t,t0), with the α1, α2, α3 factors above 35 MPa, h0 = 2Ac/u and the cement-class adjustment of t0 (B.9). No temperature adjustment is made [5].
  • Shrinkage (3.1.4 and B.2): drying shrinkage εcd = βds(t,ts)khεcd,0 and autogenous shrinkage εca = βas(t) × 2.5(fck − 10)×10⁻⁶. We use only the shrinkage that occurs after stressing, εcs = [εcd(t) − εcd(t0)] + [εca(t) − εca(t0)] [5].
  • Relaxation (3.3.2, Class 2, ρ1000 = 2.5%): Δσpr/σpi = 0.66ρ1000e9.1μ(t/1000)0.75(1−μ)×10⁻⁵, μ = σpi/fpk, σpi = σpm0. For 50 years or more we use the final value at 500,000 hours (3.3.2(8)) [5].
  • Combined time-dependent loss, eq. 5.46: Δσp,c+s+r = [εcsEp + 0.8Δσpr + (Ep/Ecm)φ(t,t0)σc,QP] / [1 + (Ep/Ecm)(Ap/Ac)(1 + (Ac/Ic)zcp²)(1 + 0.8φ(t,t0))], with σc,QP = Pm0/Ac + Pm0e²/Ic − (Mg + Msd)e/Ic and zcp = e [5]. The creep, shrinkage and relaxation shares shown are the three numerator terms divided by the common denominator.

5. Results

  • fse = fpj − friction − draw-in − elastic shortening − long-term loss. Effective force = fse × Ap per strand and for all strands, and Pe/Ac is the effective average precompression.
  • We flag an average precompression below 0.86 MPa (125 psi, given as 0.9 MPa in the SI edition), the ACI 318-19 minimum for two-way slabs [1].
  • Print gives a one-document report with inputs, results, working, date and disclaimer. Download PDF builds the same report as a PDF in your browser; nothing is sent to us. Download CSV gives the numbers for a spreadsheet.

What the calculator does

The force a tendon carries for most of its life is well below the jacking force. Friction and draw-in take part of it at stressing, the concrete shortens elastically, and then creep, shrinkage and strand relaxation keep reducing it for years. The effective force is what balances load, controls cracking and sets long-term deflection, so we check it as part of every PT slab design and review.

This calculator works the losses through for one section, to either code, and shows each step so an engineer can follow and check it. It covers the two strand sizes commonly used on building slabs in the region: 12.7 mm (0.5 in) and 15.2 mm (0.6 in) seven-wire low-relaxation strand.

ACI or Eurocode 2: what changes

  • ACI 318 option. ACI 318-19 leaves the method to the designer [1]. We use the Zia et al. component method [3], one of the approaches described in ACI 423.10R [2] and long used in PTI practice [4]. It adds four separate losses (ES, CR, SH and RE) and gives final values.
  • Eurocode 2 option. EN 1992-1-1 combines creep, shrinkage and relaxation in eq. 5.46 and allows for their interaction through the denominator [5]. Creep and shrinkage are computed from humidity, notional size, cement class, concrete strength and the ages, so early stressing and dry air show up directly in the result.

For the same slab the two options will not give identical numbers. The Eurocode method usually reacts more to young age at stressing and low humidity. That difference is real and is a good reason to run both when a project mixes code references.

How to use it

  1. Choose the code, strand size, number of strands and tendon type. For a slab, a 1,000 mm width with the strands in that width gives results per metre.
  2. Enter the concrete strength, the section depth and which faces dry. A slab cast on metal deck dries from the top only.
  3. Leave the eccentricity at 0 for an unbonded slab, where the average precompression governs. For a bonded section, enter the eccentricity and the moments at that section.
  4. Set the humidity, the end of curing and the age at stressing. Stressing at 3 days and stressing at 7 days give noticeably different creep and shrinkage.
  5. Keep friction and draw-in on and enter the tendon length, total angle change and the coefficients of the approved system, or switch them off if you only want the time-dependent part.
  6. Read the effective stress and forces, then use Print, Download PDF or Download CSV to keep the calculation with your design file.

Assumptions and limitations

  • One section, gross concrete properties, normalweight concrete and no bonded passive reinforcement. Rebar restrains creep and shrinkage and reduces the loss slightly.
  • Uncracked section under permanent load, as expected for a two-way PT slab designed to ACI 318 Class U.
  • Friction uses an evenly accumulating angle change and one-end stressing. Real profiles, two-end stressing and multi-span tendons need the actual geometry.
  • Restraint from walls, cores and stiff columns is not included. Restrained slabs lose precompression into the supports, which can matter more than the material losses.
  • No temperature adjustment for curing or service in hot climates, and no allowance for lightweight concrete.
  • Lump-sum allowances for long-term losses in unbonded flat slabs are commonly of the order of 100 to 140 MPa. Enter the figure you normally use to see how it compares with the calculation for your inputs.

For the background, read our guides on shrinkage and creep in PT slabs, friction and wobble losses and PT losses and elongation. For first sizing, try the PT slab thickness calculator.

References

The codes, standards and papers the calculator follows, consulted on 15 November 2026. Equations are reproduced for checking; always use the edition and national annex adopted for your project.

  1. American Concrete Institute: ACI 318-19 Building Code Requirements for Structural Concrete: 19.2.2 (modulus of elasticity), 20.3.2.5.1 (permissible tensile stresses in prestressed reinforcement), 20.3.2.6 (prestress losses), 8.6.2.1 (minimum average precompression in two-way slabs)
  2. ACI Committee 423: ACI 423.10R-16 Guide to Estimating Prestress Loss
  3. P. Zia, H. K. Preston, N. L. Scott and E. B. Workman, Concrete International, Vol. 1, No. 6, June 1979, pp. 32–38: “Estimating Prestress Losses” (the lump-sum-by-component method: ES, CR, SH and RE, with the Kes, Kcr, Ksh, Kre, J and C factors)
  4. Post-Tensioning Institute: Post-Tensioning Manual, 6th edition (2006): prestress losses and friction coefficients for unbonded and bonded tendons
  5. CEN: EN 1992-1-1:2004 Eurocode 2: 3.1.2 to 3.1.4 (strength gain, modulus, creep and shrinkage), 3.3.2 (relaxation), 5.10.2 to 5.10.6 (prestress limits and losses, eq. 5.46) and Annex B (creep and drying shrinkage)
  6. CEN: prEN 10138-3 Prestressing steels, Part 3: Strand (Y1860S7 strand, including 12.9 mm / 100 mm² and 15.7 mm / 150 mm²)
  7. ASTM International: ASTM A416/A416M Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Grade 270: 12.70 mm / 98.7 mm² and 15.24 mm / 140 mm²)

Part of our tools and PT design guides. Codes are referred to by clause where we are confident of the reference; always check the edition and national annex adopted for your project.

S-541 FAQ

Questions we are asked about this.

What are typical long-term prestress losses in a PT slab?

For unbonded flat slabs, the creep, shrinkage and relaxation losses often come out of the order of 80 to 150 MPa, depending on humidity, slab thickness, stressing age, precompression and the code method. Friction and draw-in come on top. Run the calculator with your own inputs rather than relying on a single figure.

Which method does the calculator use for ACI 318?

ACI 318-19 requires losses to be accounted for but does not prescribe one method. We use the component method of Zia et al. (1979), described in ACI 423.10R, which adds elastic shortening, creep, shrinkage and relaxation using published factors for post-tensioned members and low-relaxation strand.

How does the Eurocode 2 calculation work?

EN 1992-1-1 eq. 5.46 combines shrinkage strain, 0.8 times the relaxation loss and creep under the quasi-permanent concrete stress, divided by a factor that accounts for their interaction. We compute the creep coefficient from Annex B and the shrinkage strain from 3.1.4, and relaxation from 3.3.2 for Class 2 strand with a 1,000-hour value of 2.5%.

Can I use 12.9 mm or 15.7 mm Eurocode strand?

The calculator uses 12.7 mm (98.7 mm²) and 15.2 mm (140 mm²) strand. The losses in MPa hardly change for 12.9 mm (100 mm²) or 15.7 mm (150 mm²) Y1860S7 strand, but the forces scale with area, so multiply the forces by 100/98.7 or 150/140.

Should I use the average stress or the stress at a section?

For unbonded tendons, the strand stress is roughly uniform along its length, so we use the average stress after friction and draw-in. For bonded tendons, the stress at the section you are checking applies, so enter its distance from the live end.

Can I print or save the results?

Yes. Print gives a clean report with the inputs, results, working, date and disclaimer. Download PDF creates the same report as a PDF in your browser, and Download CSV gives the figures for a spreadsheet. Nothing is uploaded to our server.

S-901 Contact

Send the drawings. Get an answer from our engineers.

WhatsApp or email the architectural or structural set, the location and what you need. The reply comes from the engineers who will do the work, with a proposed scope and programme.

Office
Al Warqa 1, Dubai, UAE
Hours
Sunday – Thursday, 09:00 – 18:00 GST