Slab Edge Cracks After Stressing? Anchorage Zones
Edge cracks after stressing often start in the anchorage zone. How the force spreads, and the bursting and back-up reinforcement that protects the slab edge.

Work out the bursting force behind a post-tensioning anchorage, where it acts and how much reinforcement carries it, through the slab or beam depth and in plan. Enter the strand, jacking stress, anchorage plate and section, compare the simplified ACI 318-19 result with BS 8110 Table 4.7, and download the result as a printable report, a PDF or a CSV.
Indicative only, not a design. The results follow the methods and clauses set out below and depend on your inputs. Check them against the project drawings, the PT system documents and the code edition adopted for the project.
Edge cracks after stressing often start in the anchorage zone. How the force spreads, and the bursting and back-up reinforcement that protects the slab edge.
A post-tensioning anchorage puts the whole tendon force into the concrete through a plate a few centimetres across. As that force spreads into the full section it pulls the concrete apart across the tendon, a short distance behind the plate. That transverse tension is the bursting force, and the bars that carry it are the bursting reinforcement: hairpins and U-bars at slab edges, closed links and cages at beam ends. This calculator gives the bursting force, where it acts and the steel area for one anchorage or a closely spaced group, in both directions. For the background, local and general zones, spalling and slab-edge detailing, read our guide to anchorage zones and bursting reinforcement.
| Item | ACI 318-19 (simplified) | BS 8110-1:1997 |
|---|---|---|
| Design force | ΣPpu = 1.2 × jacking force (§5.3.13) | Po = jacking load (SLS); fpu Ap for unbonded at ULS |
| Bursting force | Tburst = 0.25 ΣPpu (1 − hanc/h) | Fbst = (Fbst/Po from Table 4.7) × Po |
| Where it acts | Centred at dburst = 0.5 (h − 2e) from the loaded face | Uniformly from 0.2yo to 2yo from the loaded face |
| Bar stress | φ fy, φ = 0.85 (Table 21.2.1) | 200 N/mm² (SLS); 0.95fy (ULS, unbonded) |
Sources: [1], [2]. EN 1992-1-1 treats anchorage zones by strut-and-tie (§8.10.3 with §6.5), with the prestressing force increased by γP,unfav (recommended value 1.2 in §2.4.2.2(3)) [3]; the strut-and-tie model for a concentrated load spreading into a prism gives a tie force of the same form as the ACI expression. Where your project follows Eurocode 2, check the strut-and-tie result and the national annex values.
Monostrand 12.7 mm strand (Ap = 98.7 mm², fpu = 1,860 MPa) stressed to 0.80fpu, bearing plate 55 mm high and 130 mm wide, anchorages at 600 mm centres, centred in a 220 mm slab. These are the calculator defaults, so you can follow the numbers on screen.
In a real slab the prescriptive slab-edge bars required with monostrand anchorages, and the hairpins shown in the PT system documents, often exceed the calculated area; provide whichever is greater.
Multistrand anchorages in beams carry forces of several thousand kN, so the bursting steel is substantial. For example, 12 × 15.2 mm strands at 0.75fpu give Pj = 2,344 kN; with a 300 mm plate in a 1,000 mm deep beam, Tburst = 0.25 × 1.2 × 2,344 × 0.7 = 492 kN and As = 1,259 mm² with fy = 460 MPa. Two or more anchorages, flanged sections, inclined tendons and anchorages near openings call for a strut-and-tie model, which is the work we do on PT transfer slabs and beams.
The codes the calculator follows, consulted on 18 November 2026. Always use the edition and national annex you will actually rely on.
Part of our free engineering tools and design guides. Clauses are referred to where we are confident of the reference; always check the edition, national annex and PT system documents adopted for your project.
Reinforcement placed across the line of a tendon just behind its anchorage to carry the transverse tension that develops as the concentrated anchorage force spreads into the full section. In slabs it is usually hairpins and edge backup bars; in beams, closed links or a cage.
Find the factored anchorage force (ACI 318-19: 1.2 times the jacking force), the bursting force Tburst = 0.25 ΣPpu (1 − hanc/h) and its centroid dburst = 0.5 (h − 2e), then As = Tburst / (0.85 fy). BS 8110 uses Table 4.7 with the bars at 200 N/mm². Do it through the depth and in plan.
By the ACI simplified method it is centred at dburst = 0.5 (h − 2e) from the loaded face, about half the depth for a centred anchorage. BS 8110 spreads the reinforcement uniformly from 0.2yo to 2yo from the loaded face.
BS 8110 designs the bars at 200 N/mm² at the serviceability limit state to keep cracks small, while ACI uses φ fy (about 357 MPa for 420 MPa bars) on a force factored by 1.2. For a slab monostrand the bursting forces are similar, so the BS area comes out larger.
Yes. Slab-edge monostrand anchorages need hairpins or U-bars and continuous backup bars along the edge, as set out in the code detailing rules and the PT system documents, and the calculated bursting steel where it is larger. Intermediate and pour-strip anchorages need the same attention.
No. Spalling tension acts at the loaded face between and around anchorages, while bursting tension acts some distance inside the member. This calculator covers bursting only; spalling and edge tension need separate checks or a strut-and-tie model.
WhatsApp or email the architectural or structural set, the location and what you need. The reply comes from the engineers who will do the work, with a proposed scope and programme.