Bursting reinforcement calculator for PT anchorage zones

Work out the bursting force behind a post-tensioning anchorage, where it acts and how much reinforcement carries it, through the slab or beam depth and in plan. Enter the strand, jacking stress, anchorage plate and section, compare the simplified ACI 318-19 result with BS 8110 Table 4.7, and download the result as a printable report, a PDF or a CSV.

Engineering disclaimer. This free tool is for preliminary checks and education only. It uses simplified code methods and your inputs, and it is not a substitute for project design. Results must be verified by a qualified structural engineer responsible for the project. Verify every result against the current code edition, national annex, authority requirements and the project drawings before use. Iron Axis accepts no liability for decisions or designs based on these results. Read the full disclaimer.
Tendon and anchorage force
ACI 318-19 Table 20.3.2.5.1: not more than 0.80fpu or 0.94fpy.
Through the depth (vertical)
Bearing plate, or the whole group.
Anchorage centre from mid-depth.
In plan (horizontal)
Anchorage spacing at a slab edge, or the beam width.
Bursting bars
Grade 60 / B420 → 420; B500 → 500; BS 4449 → 460.
Hairpin or closed link = 2.
— bursting force ACI 318-19
Step-by-step working

Indicative only, not a design. The results follow the methods and clauses set out below and depend on your inputs. Check them against the project drawings, the PT system documents and the code edition adopted for the project.

How we calculate

1. Anchorage force

  • Jacking force per anchorage Pj = jacking stress × Ap × number of strands. The stress during stressing is limited to the lesser of 0.94fpy and 0.80fpu by ACI 318-19 Table 20.3.2.5.1 [1]; the calculator warns above 80%.
  • ACI 318-19 §5.3.13 sets the design force for anchorage zones as 1.2 times the maximum jacking force, Ppu = 1.2 Pj [1]. For a group of anchorages acting together, ΣPpu is the sum.

2. ACI 318-19 simplified general-zone equations

  • ACI 318-19 §25.9 makes the designer responsible for the general zone and permits strut-and-tie, elastic analysis or, for simple cases, approximate equations (§25.9.4.4) [1]. For a rectangular prism with a straight, concentric or modestly eccentric anchorage we use Tburst = 0.25 ΣPpu (1 − hanc/h) and dburst = 0.5 (h − 2e).
  • Bursting reinforcement As = Tburst / (φ fy) with φ = 0.85 for post-tensioned anchorage zones (Table 21.2.1) [1], centred on dburst. The same equations are applied separately through the depth and in plan.
  • The calculator warns when the distance from the anchorage centre to the nearer face is less than 1.5 times the anchorage dimension, where the simplified approach is not suitable.

3. BS 8110-1 Table 4.7

  • For each direction the symmetric prism has side 2yo = h − 2e and the loaded area 2ypo = hanc. Fbst/Po is read from Table 4.7 (0.23, 0.23, 0.20, 0.17, 0.14, 0.11 for ypo/yo = 0.2 to 0.7) with linear interpolation, as the table note permits [2].
  • At the serviceability limit state Fbst is based on the tendon jacking load and the reinforcement acts at 200 N/mm², distributed uniformly from 0.2yo to 2yo from the loaded face (§4.11.2) [2]. For unbonded tendons the ultimate check uses the characteristic tendon force fpu Ap with the bars at 0.95fy (§4.11.3) [2]; the larger area is reported. Outside ypo/yo = 0.2 to 0.7 no BS value is given.

4. Reports

  • Print gives a one-document report with inputs, results, the elevation sketch, working, date and disclaimer. Download PDF builds the report as a PDF in your browser; nothing is sent to us. Download CSV gives the results, working and the Table 4.7 values used.
S-820 Video

Watch: a short explainer

Slab Edge Cracks After Stressing? Anchorage Zones

Edge cracks after stressing often start in the anchorage zone. How the force spreads, and the bursting and back-up reinforcement that protects the slab edge.

What the calculator does

A post-tensioning anchorage puts the whole tendon force into the concrete through a plate a few centimetres across. As that force spreads into the full section it pulls the concrete apart across the tendon, a short distance behind the plate. That transverse tension is the bursting force, and the bars that carry it are the bursting reinforcement: hairpins and U-bars at slab edges, closed links and cages at beam ends. This calculator gives the bursting force, where it acts and the steel area for one anchorage or a closely spaced group, in both directions. For the background, local and general zones, spalling and slab-edge detailing, read our guide to anchorage zones and bursting reinforcement.

Bursting reinforcement calculation: the formulas

Bursting force formulas used
ItemACI 318-19 (simplified)BS 8110-1:1997
Design forceΣPpu = 1.2 × jacking force (§5.3.13)Po = jacking load (SLS); fpu Ap for unbonded at ULS
Bursting forceTburst = 0.25 ΣPpu (1 − hanc/h)Fbst = (Fbst/Po from Table 4.7) × Po
Where it actsCentred at dburst = 0.5 (h − 2e) from the loaded faceUniformly from 0.2yo to 2yo from the loaded face
Bar stressφ fy, φ = 0.85 (Table 21.2.1)200 N/mm² (SLS); 0.95fy (ULS, unbonded)

Sources: [1], [2]. EN 1992-1-1 treats anchorage zones by strut-and-tie (§8.10.3 with §6.5), with the prestressing force increased by γP,unfav (recommended value 1.2 in §2.4.2.2(3)) [3]; the strut-and-tie model for a concentrated load spreading into a prism gives a tie force of the same form as the ACI expression. Where your project follows Eurocode 2, check the strut-and-tie result and the national annex values.

Worked example: 220 mm PT slab edge

Monostrand 12.7 mm strand (Ap = 98.7 mm², fpu = 1,860 MPa) stressed to 0.80fpu, bearing plate 55 mm high and 130 mm wide, anchorages at 600 mm centres, centred in a 220 mm slab. These are the calculator defaults, so you can follow the numbers on screen.

  • Pj = 0.80 × 1,860 × 98.7 = 146.9 kN; Ppu = 1.2 × 146.9 = 176.2 kN.
  • Through the depth: Tburst = 0.25 × 176.2 × (1 − 55/220) = 33.0 kN at dburst = 0.5 × 220 = 110 mm. As = 33,045 / (0.85 × 420) = 92.6 mm², so one 10 mm hairpin (two legs, 157 mm²) per anchorage covers it.
  • In plan: Tburst = 0.25 × 176.2 × (1 − 130/600) = 34.5 kN at 300 mm, As = 96.7 mm², usually provided by the backup bars along the slab edge.
  • BS 8110: ypo/yo = 55/220 = 0.25, so Fbst/Po = 0.23 and Fbst = 0.23 × 146.9 = 33.8 kN. At 200 N/mm² that needs 169 mm², spread from 22 mm to 220 mm behind the plate. The lower working stress makes the BS area larger than the ACI area.

In a real slab the prescriptive slab-edge bars required with monostrand anchorages, and the hairpins shown in the PT system documents, often exceed the calculated area; provide whichever is greater.

Beam ends and transfer girders

Multistrand anchorages in beams carry forces of several thousand kN, so the bursting steel is substantial. For example, 12 × 15.2 mm strands at 0.75fpu give Pj = 2,344 kN; with a 300 mm plate in a 1,000 mm deep beam, Tburst = 0.25 × 1.2 × 2,344 × 0.7 = 492 kN and As = 1,259 mm² with fy = 460 MPa. Two or more anchorages, flanged sections, inclined tendons and anchorages near openings call for a strut-and-tie model, which is the work we do on PT transfer slabs and beams.

Detailing reminders

References

The codes the calculator follows, consulted on 18 November 2026. Always use the edition and national annex you will actually rely on.

  1. ACI Committee 318: ACI 318-19 Building Code Requirements for Structural Concrete: §5.3.13, Table 20.3.2.5.1, Table 21.2.1, Chapter 23 and §25.9
  2. BSI: BS 8110-1:1997 Structural use of concrete, Part 1: §4.11 End blocks in post-tensioned members and Table 4.7
  3. CEN: EN 1992-1-1:2004 Eurocode 2: Design of concrete structures, Part 1-1: §2.4.2.2, §6.5 and §8.10.3

Part of our free engineering tools and design guides. Clauses are referred to where we are confident of the reference; always check the edition, national annex and PT system documents adopted for your project.

S-651 FAQ

Questions we are asked about this.

What is bursting reinforcement?

Reinforcement placed across the line of a tendon just behind its anchorage to carry the transverse tension that develops as the concentrated anchorage force spreads into the full section. In slabs it is usually hairpins and edge backup bars; in beams, closed links or a cage.

How do you calculate bursting reinforcement?

Find the factored anchorage force (ACI 318-19: 1.2 times the jacking force), the bursting force Tburst = 0.25 ΣPpu (1 − hanc/h) and its centroid dburst = 0.5 (h − 2e), then As = Tburst / (0.85 fy). BS 8110 uses Table 4.7 with the bars at 200 N/mm². Do it through the depth and in plan.

Where is the bursting force located?

By the ACI simplified method it is centred at dburst = 0.5 (h − 2e) from the loaded face, about half the depth for a centred anchorage. BS 8110 spreads the reinforcement uniformly from 0.2yo to 2yo from the loaded face.

Why does BS 8110 give more bursting steel than ACI?

BS 8110 designs the bars at 200 N/mm² at the serviceability limit state to keep cracks small, while ACI uses φ fy (about 357 MPa for 420 MPa bars) on a force factored by 1.2. For a slab monostrand the bursting forces are similar, so the BS area comes out larger.

Do PT slabs need bursting reinforcement at every anchorage?

Yes. Slab-edge monostrand anchorages need hairpins or U-bars and continuous backup bars along the edge, as set out in the code detailing rules and the PT system documents, and the calculated bursting steel where it is larger. Intermediate and pour-strip anchorages need the same attention.

Is spalling reinforcement the same as bursting reinforcement?

No. Spalling tension acts at the loaded face between and around anchorages, while bursting tension acts some distance inside the member. This calculator covers bursting only; spalling and edge tension need separate checks or a strut-and-tie model.

S-901 Contact

Send the drawings. Get an answer from our engineers.

WhatsApp or email the architectural or structural set, the location and what you need. The reply comes from the engineers who will do the work, with a proposed scope and programme.

Office
Al Warqa 1, Dubai, UAE
Hours
Sunday – Thursday, 09:00 – 18:00 GST