Lap length calculator to Eurocode 2

Work out the design anchorage length lbd and lap length l0 of reinforcing bars to EN 1992-1-1:2004, from the bond strength fbd = 2.25 η1 η2 fctd and the basic length lb,rqd, with the α1 to α6 coefficients and the minimum lengths. Every step is shown, with a printable report, a PDF and a CSV.

Engineering disclaimer. This free tool is for preliminary checks and education only. It uses simplified code methods and your inputs, and it is not a substitute for project design. Results must be verified by a qualified structural engineer responsible for the project. Verify every result against the current code edition, national annex, authority requirements and the project drawings before use. Iron Axis accepts no liability for decisions or designs based on these results. Read the full disclaimer.
Bar and materials
C30/37 is 30 MPa.
B500 = 500 MPa.
Stress at the start of the anchorage or lap, at ULS.
Figure 8.2: e.g. bars more than 250 mm above the bottom of the pour.
Shape, cover and spacing (Figure 8.3)
Confinement and laps
α6 = 1.0 below 25%, 1.15 at 33%, 1.4 at 50%, 1.5 above.
Compression across the bar, e.g. at a support. 0 if none.
Partial factors (recommended values)
Check the national annex.
— mm design lap length l0 φ16 · C30 · tension · good bond
Step-by-step working

Indicative only, not a design. The results follow the methods and clauses set out below and depend on your inputs. Check them against the project drawings, specifications and the code edition and national annex adopted for the project.

How we calculate

1. Ultimate bond stress (8.4.2)

  • fctm = 0.30 fck2/3 up to C50/60 and 2.12 ln(1 + fcm/10) above, with fcm = fck + 8 (Table 3.1). fctk,0.05 = 0.7 fctm and fctd = αct fctk,0.05/γc (3.1.6) [1].
  • fbd = 2.25 η1 η2 fctd (eq. 8.2), with η1 = 1.0 in good bond conditions and 0.7 otherwise, and η2 = 1.0 for φ ≤ 32 mm and (132 − φ)/100 above. fctd is limited to the C60/75 value, as 8.4.2(2) recommends [1].

2. Basic and design anchorage length (8.4.3 and 8.4.4)

  • lb,rqd = (φ/4)(σsd/fbd) (eq. 8.3), with σsd = fyd = fyk/γs unless you enter a lower design stress [1].
  • lbd = α1 α2 α3 α4 α5 lb,rqd ≥ lb,min (eq. 8.4), with α2 α3 α5 ≥ 0.7 (eq. 8.5). lb,min = max(0.3 lb,rqd, 10φ, 100 mm) in tension and max(0.6 lb,rqd, 10φ, 100 mm) in compression (eq. 8.6 and 8.7) [1].
  • Table 8.2 in tension: α1 = 0.7 for bent or hooked bars with cd > 3φ, else 1.0; α2 = 1 − 0.15(cd − φ)/φ for straight bars and 1 − 0.15(cd − 3φ)/φ for bent bars, between 0.7 and 1.0; α3 = 1 − Kλ between 0.7 and 1.0, with λ = (ΣAst − ΣAst,min)/As; α4 = 0.7 with welded transverse bars; α5 = 1 − 0.04p between 0.7 and 1.0. In compression α1, α2, α3 and α5 are 1.0 [1].
  • cd from Figure 8.3: min(a/2, c1, c) for straight bars and min(a/2, c1) for bent or hooked bars. K from Figure 8.4 is 0.1, 0.05 or 0 depending on where the bar sits relative to the links [1].

3. Lap length (8.7.3)

  • l0 = α1 α2 α3 α5 α6 lb,rqd ≥ l0,min (eq. 8.10), with α3 using ΣAst,min = As(σsd/fyd) and As the area of one lapped bar, and l0,min = max(0.3 α6 lb,rqd, 15φ, 200 mm) (eq. 8.11) [1].
  • α6 = (ρ1/25)0.5 between 1.0 and 1.5, where ρ1 is the percentage of reinforcement lapped within 0.65 l0 of the centre of the lap considered (Table 8.3 lists 1.0, 1.15, 1.4 and 1.5 for below 25%, 33%, 50% and above 50%) [1].
  • Print gives a one-document report with inputs, results, working, date and disclaimer. Download PDF builds the same report as a PDF in your browser; nothing is sent to us. Download CSV gives the numbers for a spreadsheet.

What the calculator does

Lap and anchorage lengths are among the most repeated numbers on a reinforcement drawing, and among the easiest to get wrong when bond conditions, cover or the percentage lapped change from one location to the next. This calculator works through EN 1992-1-1 [1] for one bar and one set of conditions, and shows each coefficient so it can be checked against the clause.

The same calculation sits behind the lap tables many offices use. Running it directly shows why a top bar in poor bond needs about 40% more length than the same bar at the bottom, and how much generous cover can save.

The main steps

  • Bond strength. fbd depends on the concrete tensile strength, the bond condition (η1) and, for bars over 32 mm, the bar size (η2).
  • Basic length. lb,rqd is the length needed to transfer the design force in the bar, φσsd/4, at the bond stress fbd.
  • Coefficients. α1 to α5 reward bent bars with enough cover, good cover and spacing, confinement, welded transverse bars and transverse pressure. α6 increases the lap length when a large share of the bars are lapped at the same section.
  • Minimums. Both the anchorage and the lap have minimum lengths that govern for small bars and low stresses.

How to use it

  1. Choose the bar diameter, fck and fyk (500 MPa for B500 bars to BS 4449 [2]). Leave σsd at fyd for a full-strength lap, or enter the lower design stress at the lap.
  2. Set tension or compression and the bond condition. Bars in the top of deep members and slabs are often in poor bond; check Figure 8.2 for your case.
  3. Enter the shape, the clear spacing and the covers. These set cd and so α1 and α2.
  4. Take α3 as 1.0, or calculate it from the transverse reinforcement. Enter any transverse pressure and the percentage of bars lapped at one section.
  5. Check the partial factors against the national annex adopted for the project.
  6. Read lbd and l0, in mm and as multiples of φ, then use Print, Download PDF or Download CSV.

Assumptions and limitations

  • Recommended values of EN 1992-1-1 are used unless you change γc, γs or αct. National annexes may set different values.
  • One bar size per calculation. For laps between different sizes, use the smaller bar's force with the appropriate bar, as your design approach requires.
  • The arrangement rules for laps in 8.7.2, the transverse reinforcement rules in 8.7.4 and the additional rules for large bars in 8.8 are flagged but not checked.
  • Bundled bars, mesh laps (8.7.5) and mechanical couplers are not covered.
  • Results are rounded up to the next millimetre. Round up again to your detailing increment.

Working to ACI 318 instead? Use our development length calculator to ACI 318-19. For bar weights, use the rebar weight calculator, and for reinforcement behind PT anchors, read our guide to PT anchorage zone bursting reinforcement.

References

The codes and standards the calculator follows, consulted on 15 November 2026. Clause numbers are given so you can check each step; always use the edition and national annex adopted for your project.

  1. CEN: EN 1992-1-1:2004 Eurocode 2: Design of concrete structures, Part 1-1: 3.1.2 and Table 3.1 (fctm, fctk,0.05), 3.1.6 (fctd), 8.4 (anchorage, eq. 8.2 to 8.7, Table 8.2, Figures 8.3 and 8.4), 8.7 (laps, eq. 8.10 and 8.11, Table 8.3) and 8.8 (large diameter bars)
  2. BSI: BS 4449:2005+A3:2016 Steel for the reinforcement of concrete. Weldable reinforcing steel. Bar, coil and decoiled product. Specification (nominal sizes, cross-sectional areas and mass per metre)

Part of our free engineering tools and design guides. Codes are referred to by clause where we are confident of the reference; always check the edition and national annex adopted for your project.

S-581 FAQ

Questions we are asked about this.

What is the lap length of a 16 mm bar to Eurocode 2?

For a straight 16 mm B500 bar in tension in C30/37 concrete, good bond, 30 mm cover and 100 mm clear spacing, lb,rqd is about 572 mm. With α2 = 0.87 and half the bars lapped at one section (α6 = 1.41), l0 is about 703 mm, or 44φ. With α2 and α3 taken as 1.0 it would be about 809 mm.

What is the difference between lbd and l0?

lbd is the design anchorage length of a bar ending in concrete. l0 is the design lap length where one bar transfers its force to another. The lap uses the same basic length with α6 for the percentage lapped and has a higher minimum length.

When are bond conditions poor?

EN 1992-1-1 Figure 8.2 covers bars at less than 45° to the horizontal. Members up to 250 mm deep are in good bond throughout. In members up to 600 mm deep, bars more than 250 mm above the bottom of the pour are in poor bond, and in deeper members, bars within 300 mm of the top. Poor bond means η1 = 0.7, which makes the length about 43% longer.

How is α6 worked out?

α6 = (ρ1/25)^0.5, limited to between 1.0 and 1.5, where ρ1 is the percentage of bars lapped within 0.65 l0 of the centre of the lap. Table 8.3 gives 1.0 below 25%, 1.15 at 33%, 1.4 at 50% and 1.5 above 50%.

Can I take all the α coefficients as 1.0?

Yes, it is conservative to take α1 to α5 as 1.0. The lap length then becomes α6 lb,rqd, which is what many quick lap tables use.

Can I print or save the results?

Yes. Print gives a clean report with the inputs, results, working, date and disclaimer. Download PDF creates the same report as a PDF in your browser, and Download CSV gives the figures for a spreadsheet. Nothing is uploaded to our server.

S-901 Contact

Send the drawings. Get an answer from our engineers.

WhatsApp or email the architectural or structural set, the location and what you need. The reply comes from the engineers who will do the work, with a proposed scope and programme.

Office
Al Warqa 1, Dubai, UAE
Hours
Sunday – Thursday, 09:00 – 18:00 GST