1. Home
  2. Tools
  3. Load combination calculator
Free tool  ·  Indicative  ·  Iron Axis engineering team

Load combination calculator: ASCE 7-16, ASCE 7-22 and EN 1990

Enter your unfactored load effects (axial force, moment, shear or pressure, in any consistent unit) and get every LRFD and ASD combination of ASCE 7-16 or ASCE 7-22, or the Eurocode EN 1990 ULS and SLS combinations, with wind and seismic in both directions and the governing case picked out.

Engineering disclaimer. This free tool is for preliminary checks and education only. It uses simplified code methods and your inputs, and it is not a substitute for project design. Results must be verified by a qualified structural engineer responsible for the project. Verify every result against the current code edition, national annex, authority requirements and the project drawings before use. Iron Axis accepts no liability for decisions or designs based on these results. Read the full disclaimer.
Standard
Unfactored load effects (same unit for all)
Self-weight plus superimposed dead.
Applied as +W and −W.
ρQE, applied as ±Eh.
For Ev = 0.2 SDS D.
— governing value
Step-by-step working

Indicative only. Combinations of the effects you enter; load values and any special combinations come from the project.

How we calculate

1. ASCE 7-16 and ASCE 7-22

  • Strength design (LRFD) combinations 1 to 5 of §2.3.1 and the seismic combinations 6 and 7 of §2.3.6, with Ev = 0.2SDS D (§12.4.2.2). Allowable stress (ASD) combinations 1 to 7 of §2.4.1 and 8 to 10 of §2.4.5 [1][2].
  • ASCE 7-22 changed the snow terms because snow loads are now mapped at strength level: 0.3S instead of 0.5S in combinations 2 and 4, 1.0S instead of 1.6S in combination 3, 0.15S in the seismic combination, and 0.7S in ASD [2]. We use the edition you choose.
  • “Lr or S or R” terms are tried one at a time, and wind and horizontal seismic are applied in both directions, so a minimum (uplift or reversal) is found as well as a maximum.

2. EN 1990

  • ULS STR combinations from Table A1.2(B): eq. 6.10 (1.35G + 1.5Qk,1 + 1.5ψ0Qk,i) or the pair 6.10a (1.35G + 1.5ψ0Q) and 6.10b (ξ1.35G + 1.5Qk,1 + 1.5ψ0Qk,i) with ξ = 0.85; each variable action is taken as leading in turn, and favourable G uses γG,inf = 1.0 [3].
  • SLS characteristic, frequent and quasi-permanent combinations (eq. 6.14b to 6.16b) with the recommended ψ0, ψ1, ψ2 of Table A1.1: snow 0.5/0.2/0 and wind 0.6/0.2/0 for sites below 1,000 m [3].

What the load combinations are for

Codes do not let you simply add up all the loads. Each combination pairs one variable load at its full design value with the others reduced to the value likely to be present at the same time. The worst result of all combinations governs, and it can be a minimum as well as a maximum: wind uplift on a light roof or overturning of a tall frame is governed by 0.9D − W, not by 1.2D + 1.6L.

Worked example (ASCE 7-16)

With D = 100, L = 50, Lr = 10, W = ±40 and Eh = ±30 (for example in kN) and SDS = 0.5:

  • 1.2D + 1.6L + 0.5Lr = 205; 1.2D + 1.0W + L + 0.5Lr = 215 governs the maximum; 1.2D + Ev + Eh + L = 210.
  • The minimum is 0.9D − W = 50, from wind, and 0.9D − Ev − Eh = 50 from seismic.
  • The ASD maximum is D + 0.75L + 0.45W + 0.75Lr = 163.

The same loads to EN 1990

For category B (offices) with eq. 6.10a and 6.10b, the governing ULS value is 1.1475G + 1.05Q + 1.5W = 227.3, with wind leading. Eq. 6.10 alone gives 1.35G + 1.05Q + 1.5W = 247.5 with wind leading, which is simpler and more conservative. National annexes may change the partial factors and ψ values; check the annex for your country.

Using the results

Put a factored load per m² or per metre straight into our continuous beam calculator, or factored axial loads into the RC column and footing calculators. Load values themselves (live load per occupancy, wind and seismic) come from the code and the project; our slab load calculator builds up gravity loads per m².

References

The codes and texts the calculator follows, consulted on 19 November 2026. Always use the edition and national annex you will actually rely on.

  1. ASCE: ASCE/SEI 7-16 Minimum Design Loads and Associated Criteria for Buildings and Other Structures: §2.3, §2.4 and §12.4.2.2
  2. ASCE: ASCE/SEI 7-22 Minimum Design Loads and Associated Criteria for Buildings and Other Structures: Chapter 2 load combinations
  3. CEN: EN 1990:2002+A1:2005 Eurocode, Basis of structural design: §6.4.3.2, §6.5.3 and Annex A1 (Tables A1.1 and A1.2(B))

Part of our free engineering tools and design guides. Results are for preliminary design and checking, and must be verified by a qualified structural engineer responsible for the project. Clauses are referred to where we are confident of the reference; always check the edition and national annex adopted for your project.

S-751 FAQ

Questions we are asked about this.

What are the ASCE 7-16 LRFD load combinations?

1.4D; 1.2D + 1.6L + 0.5(Lr or S or R); 1.2D + 1.6(Lr or S or R) + (L or 0.5W); 1.2D + 1.0W + L + 0.5(Lr or S or R); 0.9D + 1.0W; and the seismic combinations 1.2D + Ev + Eh + L + 0.2S and 0.9D − Ev + Eh.

What changed in ASCE 7-22 load combinations?

Snow is now a strength-level load, so its factors fell: 0.3S in combinations 2 and 4, 1.0S in combination 3, 0.15S with seismic, and 0.7S in ASD. The other combinations are unchanged in form.

What is the difference between LRFD and ASD combinations?

LRFD (strength design) factors the loads up and compares them with factored resistances, as in ACI 318 and AISC LRFD. ASD keeps loads near service level and compares them with allowable stresses, as in AISC ASD and allowable bearing pressure for foundations.

What are 6.10a and 6.10b in EN 1990?

An alternative to eq. 6.10: 6.10a is 1.35G + 1.5ψ0Q for all variable actions and 6.10b is 0.85 × 1.35G + 1.5Q for the leading action plus 1.5ψ0Q for the others. Design for the worse of the two; it is usually lighter than 6.10 alone.

Why is 0.9D used?

When dead load helps resist uplift, overturning or sliding, a lower dead load is the worse case. ASCE 7 uses 0.9D in LRFD and 0.6D in ASD; EN 1990 uses γG,inf = 1.0 for STR.

Can I enter moments instead of loads?

Yes. Any load effect works (axial force, shear, moment or pressure) as long as every input is the effect of that load case on the same member and in the same unit.

S-901 Contact

Send the drawings. Get an answer from our engineers.

WhatsApp or email the architectural or structural set, the location and what you need. The reply comes from the engineers who will do the work, with a proposed scope and programme.

Office
Al Warqa 1, Dubai, UAE
Hours
Sunday – Thursday, 09:00 – 18:00 GST