Isolated footing design calculator to ACI 318-19
Size a square or rectangular pad footing under a column and check it to ACI 318-19. Get the plan size from the allowable bearing pressure, the punching and one-way shear checks, the bending steel and bar spacing each way, and the thickness needed, with every step shown.
Step-by-step working
Indicative only. Concentric load, uniform soil pressure; the bearing value must come from a geotechnical report.
How we calculate
1. Plan size
- Net allowable pressure qn = qa − γc h − γs (Df − h) − surcharge, with concrete at 24 kN/m³. Required area A = (PD + PL)/qn, rounded up to 50 mm in each direction for the length to width ratio you choose.
- Factored pressure qu = (γD PD + γL PL)/A, uniform because the load is concentric [1].
2. Shear (ACI 318-19)
- d = h − cover − db, averaged over the two layers. Punching at d/2 from the column face: vc = the least of 0.33λs λ√fc′, 0.17(1 + 2/β)λs λ√fc′ and 0.083(2 + αs d/bo)λs λ√fc′ (Table 22.6.5.2), with λs = √(2/(1 + 0.004d)) ≤ 1 (§22.5.5.1.3) and αs = 40 for an interior column; φ = 0.75 [1].
- One-way shear at d from the column face: φVc = 0.75 × 0.66λs λ (ρw)^⅓ √fc′ b d (Table 22.5.5.1(c)), because footings have no shear reinforcement [1].
3. Flexure
- Moment at the face of the column (§13.2.7.1): Mu = qu B (L − c)²/8 each way. As from the Whitney block with φ = 0.9, not less than 0.0018 B h (the slab minimum of §8.6.1.1 and §7.6.1.1). Spacing ≤ min(3h, 450 mm). For rectangular footings the short-direction steel is concentrated in the central band by γs = 2/(β + 1) (§13.3.3.3) [1].
- If the thickness you enter fails a shear check, the calculator also finds the smallest thickness, in 25 mm steps, that passes.
Worked example
A 400 × 400 mm column carries PD = 800 kN and PL = 400 kN. The allowable bearing pressure is 250 kPa at 1.5 m depth, the footing is 600 mm thick, fc′ = 28 MPa and fy = 420 MPa:
- qn = 250 − 24 × 0.6 − 18 × 0.9 = 219.4 kPa, so A = 1,200/219.4 = 5.47 m² and a 2.35 × 2.35 m footing (5.52 m²).
- qu = (1.2 × 800 + 1.6 × 400)/5.52 = 289.7 kPa; d = 600 − 75 − 16 = 509 mm; λs = 0.81.
- Punching: Vu = 1,361 kN against φVc = 1,967 kN (69%). One-way shear: 317 kN against 330 kN (96%), so one-way shear governs the thickness here.
- Flexure: Mu = 289.7 × 2.35 × 0.975² / 2 = 324 kN·m each way, giving 13Ø16 each way.
Why the size effect matters for footings
ACI 318-19 introduced the size-effect factor λs for members without shear reinforcement. A 600 mm footing with d = 509 mm loses about 19% of its concrete shear strength compared with the 2014 code, which often makes one-way shear, rather than punching, decide the thickness. Older spreadsheets that ignore λs can give footings that are too thin.
Limits of this calculator
- Concentric load only. Moments, uplift and eccentric loads give a non-uniform pressure and need a different check.
- Settlement, the bearing capacity itself and soil conditions come from the geotechnical engineer.
- Development of the bars, the column dowels and bearing at the column base (§22.8) are not checked.
Use our RC column calculator for the column above and our concrete volume calculator to order the concrete. The punching shear guide explains the bo and αs terms in more detail.
References
The codes and texts the calculator follows, consulted on 19 November 2026. Always use the edition and national annex you will actually rely on.
Part of our free engineering tools and design guides. Results are for preliminary design and checking, and must be verified by a qualified structural engineer responsible for the project. Clauses are referred to where we are confident of the reference; always check the edition and national annex adopted for your project.
Questions we are asked about this.
How do you calculate the size of an isolated footing?
Divide the service load (dead plus live) by the net allowable bearing pressure: the gross allowable pressure minus the weight of the footing, the soil above it and any surcharge. Then round the sides up.
How thick should a pad footing be?
Thick enough for punching and one-way shear without shear reinforcement. ACI 318-19 §13.3.1.2 also requires an effective depth of the bottom steel of at least 150 mm. 500 to 900 mm is common for columns carrying 1,000 to 3,000 kN.
Where is the critical section for punching shear in a footing?
At d/2 from the face of the column, all round (ACI 318-19 §22.6.4.1). For one-way shear the critical section is at d from the face.
What is the minimum reinforcement for a footing?
ACI 318-19 uses the shrinkage and temperature minimum of 0.0018 times the gross area for Grade 420 bars, with spacing not more than 3h or 450 mm.
Why do I need factored and unfactored loads?
The plan size uses service loads against the allowable bearing pressure; shear and bending are designed for factored loads (1.2D + 1.6L) to ACI 318-19.
Does the calculator consider moments on the footing?
No. It assumes a concentric load and uniform pressure. Footings with moments or horizontal loads need an eccentric pressure and stability check.
Send the drawings. Get an answer from our engineers.
WhatsApp or email the architectural or structural set, the location and what you need. The reply comes from the engineers who will do the work, with a proposed scope and programme.
- +971 52 118 2569
- Telephone
- +971 52 118 2569
- Office
- Al Warqa 1, Dubai, UAE
- Hours
- Sunday – Thursday, 09:00 – 18:00 GST