1. Home
  2. Tools
  3. Retaining wall design calculator
Free tool  ·  Indicative  ·  Iron Axis engineering team

Retaining wall design calculator for cantilever RC walls

Check a reinforced concrete cantilever retaining wall for overturning, sliding and bearing, then size the vertical steel in the stem. Enter the wall geometry, the soil and the surcharge, and see the earth pressure, every force and lever arm, and the safety factors step by step.

Engineering disclaimer. This free tool is for preliminary checks and education only. It uses simplified code methods and your inputs, and it is not a substitute for project design. Results must be verified by a qualified structural engineer responsible for the project. Verify every result against the current code edition, national annex, authority requirements and the project drawings before use. Iron Axis accepts no liability for decisions or designs based on these results. Read the full disclaimer.
Wall geometry (m)
Back face battered if larger than the top.
In front of the stem.
Behind the stem, under the backfill.
Soil
e.g. 10 for light traffic or pedestrians.
0 = tan(2φ/3).
0 = ignore passive (usual).
Safety factors
IBC 2021 §1807.2.3: 1.5.
Stem design
ACI 318-19: 40 mm (bars ≤ Ø16) or 50 mm exposed to earth; 75 cast against earth.
— stability check
Step-by-step working

Indicative only. Drained, level backfill with Rankine pressure; soil parameters must come from a geotechnical report.

How we calculate

1. Earth pressure

  • Rankine active coefficient Ka = (1 − sin φ)/(1 + sin φ) for level backfill, acting on a vertical plane through the end of the heel over the full height H′ = H + base thickness [1].
  • Soil thrust Pa = ½ Ka γ H′² at H′/3; surcharge thrust Pq = Ka q H′ at H′/2. The backfill is assumed drained, so no water pressure acts.

2. Stability (service loads)

  • Resisting moment about the toe from the base, the stem and the soil over the heel. The surcharge on the heel is left out of the resisting side, following IBC 2021 §1807.2.3, which sets the safety factor at 1.5 for both sliding and overturning with variable loads at zero [2].
  • Sliding resistance μ ΣV plus the passive pressure on the toe if you enter a depth (Kp = 1/Ka). μ defaults to tan(2φ/3) if you enter 0.
  • Bearing: e = B/2 − (ΣMr − Mo)/ΣV; q = ΣV/B (1 ± 6e/B) when e ≤ B/6, otherwise a triangular pressure 2ΣV/(3(B/2 − e)).

3. Stem (ACI 318-19)

  • Stem base moment and shear from the earth and surcharge pressure on the stem height, factored by 1.6 for lateral earth pressure (§5.3.8) [3].
  • Vertical steel from the Whitney block with φ = 0.9, not less than 0.0018bh, the one-way slab minimum of Table 7.6.1.1; shear without stirrups by Table 22.5.5.1(c) with λs [3].

Worked example (the defaults)

A 3.0 m retained height on a 0.4 m base with a 0.8 m toe and 2.0 m heel (B = 3.1 m), a stem 0.25 m at the top and 0.3 m at the base, backfill at 18 kN/m³ with φ = 30°, 10 kPa surcharge and μ = 0.5:

  • Ka = 1/3; H′ = 3.4 m. Pa = ½ × ⅓ × 18 × 3.4² = 34.7 kN/m; Pq = ⅓ × 10 × 3.4 = 11.3 kN/m; overturning moment 58.6 kN·m/m.
  • ΣV = 158.9 kN/m and ΣMr = 293.0 kN·m/m, so FS overturning = 5.0 and FS sliding = 0.5 × 158.9 / 46.0 = 1.73, both above 1.5.
  • e = 0.075 m, inside B/6, so the bearing pressure is 58.7 kPa at the toe and 43.8 kPa at the heel.
  • Stem: Mu = 1.6 × 42.0 = 67.2 kN·m/m with d = 242 mm, giving Ø16 @ 250 mm on the soil face.

Sizing a cantilever wall

Common starting proportions are a base width of 0.5 to 0.7 times the total height, a toe of about a third of the base, and a stem thickness at the base of about H/10 to H/12, with at least 200 to 250 mm at the top. Sliding is usually the critical check: a longer heel adds soil weight, and a shear key under the base can mobilise passive resistance when the geotechnical engineer accepts it.

What this calculator leaves out

  • Groundwater behind the wall. Without drainage, water pressure can double the thrust. Weep holes and a drainage layer are essential.
  • Sloping backfill, compaction pressure, seismic earth pressure, at-rest pressure for restrained walls (basement walls), and global slope stability.
  • Design of the toe and heel slabs and the anchorage of stem bars into the base.

Use the footing calculator for column bases and the concrete volume calculator for quantities.

References

The codes and texts the calculator follows, consulted on 19 November 2026. Always use the edition and national annex you will actually rely on.

  1. B. M. Das: Principles of Foundation Engineering: Rankine active pressure and stability of retaining walls (any recent edition)
  2. ICC: International Building Code 2021: §1807.2 retaining walls (§1807.2.3 safety factor)
  3. ACI: ACI 318-19 Building Code Requirements for Structural Concrete: §5.3.8, Table 7.6.1.1, Table 20.5.1.3.1 and Table 22.5.5.1

Part of our free engineering tools and design guides. Results are for preliminary design and checking, and must be verified by a qualified structural engineer responsible for the project. Clauses are referred to where we are confident of the reference; always check the edition and national annex adopted for your project.

S-771 FAQ

Questions we are asked about this.

What safety factors are used for retaining walls?

IBC 2021 §1807.2.3 requires a factor of safety of 1.5 against sliding and overturning. Many designers also keep the resultant within the middle third of the base under service loads.

How do you calculate active earth pressure?

With Rankine theory for level backfill, Ka = (1 − sin φ)/(1 + sin φ), and the thrust is ½ Ka γ H² acting at H/3. For φ = 30°, Ka = 1/3.

How wide should the base of a retaining wall be?

Typically 0.5 to 0.7 times the total height, with the toe about a third of the base. The exact width comes from the sliding, overturning and bearing checks.

What friction coefficient should I use under the base?

A common value is tan(2φ/3) for concrete cast on granular soil, often 0.4 to 0.55. The geotechnical report should give it.

Why is the surcharge on the heel ignored for stability?

A surcharge such as traffic may not be present when the thrust is acting. IBC §1807.2.3 sets variable loads to zero for these checks, so the calculator leaves it out of the resisting forces.

Can I use this for a basement wall?

No. A basement wall propped by floors is restrained and carries at-rest pressure and often water pressure; it is designed as a slab spanning between floors, not as a cantilever.

S-901 Contact

Send the drawings. Get an answer from our engineers.

WhatsApp or email the architectural or structural set, the location and what you need. The reply comes from the engineers who will do the work, with a proposed scope and programme.

Office
Al Warqa 1, Dubai, UAE
Hours
Sunday – Thursday, 09:00 – 18:00 GST