Work out the load on a concrete floor slab: self-weight, screed, finishes, ceiling, partitions and live load, in kN/m², kg/m² and psf. Get the factored load to ACI 318 / ASCE 7 and Eurocode, and the line load on the beam that supports it.
Step-by-step working
Indicative only. Loads must follow the code and occupancy adopted for the project.
How we calculate
1. Dead load
- Self-weight = γc × h; screed = γs × t. EN 1991-1-1 Table A.1 gives 25 kN/m³ for normal-weight reinforced concrete (24 plain, +1 for wet concrete) and 19–23 kN/m³ for cement mortar, which covers most screeds [1].
- Finishes, ceiling, services and other superimposed dead loads are added as entered.
2. Partitions and live load
- EN 1991-1-1 §6.3.1.2(8) allows movable partitions to be taken as a uniform imposed load of 0.5, 0.8 or 1.2 kN/m² for partitions weighing up to 1.0, 2.0 or 3.0 kN/m of wall length [1]. ASCE 7-16 §4.3.2 requires a 15 psf (0.72 kN/m²) partition allowance in offices where partitions may move, unless the specified live load is 80 psf or more [2].
- Live load presets are the uniform loads of ASCE 7-16 Table 4.3-1, converted with 1 psf = 0.04788 kN/m² [2]. Live load reduction is not applied.
3. Factored and beam loads
Worked example: residential floor
A 200 mm slab with a 50 mm screed, 0.5 kN/m² finishes, 0.5 kN/m² ceiling and services, movable partitions of up to 2 kN/m taken as 0.8 kN/m² imposed load, and residential live load (40 psf):
- Dead load D = 25 × 0.2 + 22 × 0.05 + 0.5 + 0.5 = 5.0 + 1.1 + 1.0 = 7.10 kN/m² (724 kg/m²).
- Live load L = 1.92 + 0.80 = 2.72 kN/m².
- Factored: 1.2 × 7.10 + 1.6 × 2.72 = 12.86 kN/m² (ACI/ASCE 7), or 1.35 × 7.10 + 1.5 × 2.72 = 13.66 kN/m² (EN 1990 eq. 6.10).
Typical slab dead loads
| Thickness | kN/m² | kg/m² | psf |
|---|---|---|---|
| 150 mm | 3.75 | 382 | 78 |
| 200 mm | 5.00 | 510 | 104 |
| 250 mm | 6.25 | 637 | 131 |
| 300 mm | 7.50 | 765 | 157 |
Post-tensioned flat slabs are usually thinner than RC slabs for the same span, which cuts the dead load on columns and foundations. Compare the two with our RC vs PT slab calculator.
Live load: which code?
Many Gulf projects follow the International Building Code, which refers to ASCE 7 for live loads, so the presets use ASCE 7-16 Table 4.3-1. Eurocode projects should take qk from EN 1991-1-1 Table 6.2 and its national annex, for example 1.5–2.0 kN/m² for dwellings and 2.0–3.0 kN/m² for offices; choose “Enter my own”. Then design the slab with our one-way slab calculator, combine loads with the load combination calculator, or convert units with the unit converter.
References
The codes and texts the calculator follows, consulted on 19 November 2026. Always use the edition and national annex you will actually rely on.
- CEN: EN 1991-1-1:2002 Eurocode 1, Actions on structures, Part 1-1: Annex A Table A.1, §6.3.1.2 and Table 6.2
- ASCE: ASCE/SEI 7-16 Minimum Design Loads: §2.3.1, §4.3.2 and Table 4.3-1
- CEN: EN 1990:2002+A1:2005 Eurocode, Basis of structural design: eq. 6.10 and Table A1.2(B)
Part of our free engineering tools and design guides. Results are for preliminary design and checking, and must be verified by a qualified structural engineer responsible for the project. Clauses are referred to where we are confident of the reference; always check the edition and national annex adopted for your project.
Questions we are asked about this.
How do you calculate the dead load of a slab?
Multiply the thickness by the unit weight of reinforced concrete (25 kN/m³), then add screed, finishes, ceilings, services and fixed partitions. A 200 mm slab weighs 5.0 kN/m², about 510 kg/m².
What is the live load for a residential floor?
ASCE 7-16 Table 4.3-1 gives 40 psf (1.92 kN/m²) for dwellings. EN 1991-1-1 Table 6.2 recommends 1.5 to 2.0 kN/m² for category A floors; the national annex sets the value.
How much load should I allow for partitions?
EN 1991-1-1 allows 0.5, 0.8 or 1.2 kN/m² for movable partitions up to 1, 2 or 3 kN/m run. ASCE 7 requires 15 psf (0.72 kN/m²) in offices. Heavy masonry walls should be modelled as line loads.
What is the factored load on a slab?
To ACI 318 and ASCE 7, wu = 1.2D + 1.6L (but not less than 1.4D). To Eurocode, 1.35G + 1.5Q with eq. 6.10.
How do I convert kN/m² to kg/m²?
Multiply by 101.97. For example 5 kN/m² = 510 kg/m². Our structural unit converter does all the common load units.
How do I find the load on a beam from a slab?
Multiply the slab load per m² by the tributary width (half the span on each side for a one-way slab) and add the beam’s own weight below the slab.
Send the drawings. Get an answer from our engineers.
WhatsApp or email the architectural or structural set, the location and what you need. The reply comes from the engineers who will do the work, with a proposed scope and programme.
- +971 52 118 2569
- Telephone
- +971 52 118 2569
- Office
- Al Warqa 1, Dubai, UAE
- Hours
- Sunday – Thursday, 09:00 – 18:00 GST