One-way slab design calculator to ACI 318-19
Design a solid one-way slab strip: minimum thickness, factored load, moments from the ACI coefficients, bottom and top bar spacing, shrinkage steel and the shear check. Choose a simply supported, end, interior or cantilever span and follow every step.
Step-by-step working
Indicative only. Approximate ACI coefficients for roughly equal spans under uniform load; deflection is not calculated.
How we calculate
1. Thickness and loads
- Minimum thickness from ACI 318-19 Table 7.3.1.1: ℓ/20 simply supported, ℓ/24 one end continuous, ℓ/28 both ends continuous, ℓ/10 cantilever, multiplied by (0.4 + fy/700) for fy other than 420 MPa [1].
- wu = the larger of 1.2 (γc h + SDL) + 1.6 L and 1.4 (γc h + SDL) on a 1 m strip (ACI 318-19 §5.3.1, eq. (a) and (b)).
2. Moments and shear
- Approximate coefficients of Table 6.5.2 on the clear span ℓn: wu ℓn²/11 or /14 in end spans, /16 in interior spans, /9 or /10 at the first interior support, /11 at other interior supports, and /24 or /16 at exterior supports integral with a spandrel or column. Shear 1.15 wu ℓn/2 at the first interior support, wu ℓn/2 elsewhere (Table 6.5.4) [1].
- Simply supported spans use wu ℓn²/8 and cantilevers wu ℓn²/2.
3. Steel and shear check
- d = h − cover − db/2; As from the Whitney block with φ = 0.9. As,min = 0.0018 b h (Table 7.6.1.1, also the shrinkage and temperature steel of §24.4.3.2). Spacing ≤ min(3h, 450 mm) for main bars and min(5h, 450 mm) for shrinkage steel; spacings are rounded down to a practical step [1].
- φVc = 0.75 × 0.66λs (ρw)^⅓ √fc′ b d (Table 22.5.5.1(c)), with λs = √(2/(1 + 0.004d)) ≤ 1, since slabs have no shear reinforcement [1].
Worked example: interior span
An interior span of a continuous one-way slab, 4.5 m centre to centre on 300 mm beams, SDL = 1.5 kN/m², live load 4 kN/m², fc′ = 28 MPa, fy = 420 MPa, Ø10 bars with 20 mm cover (the defaults):
- hmin = 4,500/28 = 161 mm, rounded to 170 mm. Self-weight 24 × 0.17 = 4.08 kN/m².
- wu = 1.2 × (4.08 + 1.5) + 1.6 × 4 = 13.10 kN/m²; ℓn = 4.2 m.
- Midspan: M+ = 13.10 × 4.2²/16 = 14.4 kN·m/m. With d = 145 mm the steel needed is less than the 0.0018bh minimum of 306 mm²/m, so Ø10 @ 250 mm (314 mm²/m).
- Supports: M− = 13.10 × 4.2²/11 = 21.0 kN·m/m, needing 393 mm²/m: Ø10 @ 200 mm top.
- Shear: Vu = 13.10 × 4.2/2 = 27.5 kN/m against φVc = 52.9 kN/m, so no shear reinforcement is needed.
When is a slab one-way?
A slab supported on two opposite sides, or a panel with a long-to-short side ratio of more than about 2, carries load mainly in the short direction and is designed as one-way. Square-ish panels supported on all four sides are two-way slabs and need a different method. Post-tensioned slabs span much further for the same thickness; see our PT slab thickness calculator and the RC vs PT slab calculator.
When the coefficients do not apply
ACI 318-19 §6.5.1 allows the coefficients only for at least two spans, roughly equal spans (the larger of two adjacent spans not more than 20% longer than the shorter), uniform load, L ≤ 3D and prismatic members. Outside these limits, analyse the slab strip with our continuous beam calculator and design the sections from those moments.
Deflection is not calculated: slabs at least as thick as Table 7.3.1.1 need no deflection calculation unless they support partitions likely to be damaged by large deflections. Get the loads from our slab load calculator.
References
The codes and texts the calculator follows, consulted on 19 November 2026. Always use the edition and national annex you will actually rely on.
Part of our free engineering tools and design guides. Results are for preliminary design and checking, and must be verified by a qualified structural engineer responsible for the project. Clauses are referred to where we are confident of the reference; always check the edition and national annex adopted for your project.
Questions we are asked about this.
What is the minimum thickness of a one-way slab?
ACI 318-19 Table 7.3.1.1: span/20 for simply supported, /24 for one end continuous, /28 for both ends continuous and /10 for cantilevers, for fy = 420 MPa and normal-weight concrete.
How do you design a one-way slab?
Find the thickness, the factored load per m², the moments and shears on a 1 m strip, then the steel area and spacing for each moment, and check the shear without stirrups. Add shrinkage steel in the other direction.
What is the ACI moment coefficient for an interior span?
Positive moment wu ℓn²/16 at midspan and negative moment wu ℓn²/11 at interior supports, or wu ℓn²/10 at the first interior support of a slab with more than two spans.
What is the maximum bar spacing in a slab?
Main bars: the lesser of 3h and 450 mm (ACI 318-19 §7.7.2.3). Shrinkage and temperature bars: the lesser of 5h and 450 mm (§24.4.3.3).
How much shrinkage steel does a slab need?
0.0018 times the gross area for Grade 420 deformed bars (ACI 318-19 Table 24.4.3.2), in the direction perpendicular to the main steel.
When is a slab two-way?
When it is supported on all four sides and the longer side is less than about twice the shorter. Two-way slabs need a different method, such as the direct design method or a finite element analysis.
Send the drawings. Get an answer from our engineers.
WhatsApp or email the architectural or structural set, the location and what you need. The reply comes from the engineers who will do the work, with a proposed scope and programme.
- +971 52 118 2569
- Telephone
- +971 52 118 2569
- Office
- Al Warqa 1, Dubai, UAE
- Hours
- Sunday – Thursday, 09:00 – 18:00 GST
