Stair calculator: risers, treads, pitch and concrete
Enter the floor-to-floor height and the going you want, and get the number of risers, the riser height, the total run and the pitch, checked against the IBC, the IRC or UK Approved Document K. Add the width and waist to estimate the concrete for a straight or dog-leg stair.
Step-by-step working
Indicative only. Check the stair against the building code, fire and accessibility rules adopted for the project.
How we calculate
1. Risers and treads
- Number of risers n = H / Rmax rounded up (to an even number for two equal flights), then R = H / n. Each flight has one tread fewer than risers because the top step is the floor or landing.
- Run = treads × going; pitch = atan(R/G); comfort rule 2R + G, which Approved Document K requires to be 550 to 700 mm [3].
2. Limits checked
- IBC 2021 §1011.5.2: riser 4 to 7 in (102 to 178 mm), tread at least 11 in (279 mm) [1].
- IRC 2021 §R311.7.5: riser not more than 7¾ in (196 mm), tread at least 10 in (254 mm) [2].
- Approved Document K Table 1.1: private stair rise 150–220 mm, going 220–300 mm, pitch ≤ 42°; general access 150–170 / 250–400 mm; utility 150–190 / 250–400 mm [3].
3. Concrete
- Waist slab = slope length × waist × width per flight; steps = treads × ½ R G × width; half landing = landing length × waist × twice the width.
How many steps do I need?
Divide the floor-to-floor height by the maximum riser and round up. For 3,200 mm under the IBC limit of 178 mm: 3,200/178 = 17.98, so 18 risers of 177.8 mm. In a dog-leg stair that is two flights of 9 risers and 8 treads each, 16 treads in total. With a 280 mm going each flight is 2,240 mm long and the pitch is 32.4°.
UK example from Approved Document K
For a private stair with 2,700 mm floor-to-floor and a 250 mm going, the calculator gives 13 risers of 207.7 mm, a pitch of 39.7° and 2R + G = 665 mm, inside the 550–700 mm range and below the 42° maximum.
Rules worth knowing
- Keep every riser and every going in a flight the same. The IBC and IRC limit the difference between the largest and smallest to 3/8 in (9.5 mm).
- Headroom: 80 in (2,032 mm) under the IBC and 6 ft 8 in under the IRC; 2.0 m in Approved Document K, with relaxations for loft conversions.
- Gulf authorities often adopt the IBC or their own fire and life-safety codes, which may be stricter for exit stairs. Use the code your authority requires.
The concrete estimate covers a cast in-situ stair. For quantities of other elements use the concrete volume calculator, and for the bars the rebar weight calculator. A stair is structurally a sloping one-way slab; see our one-way slab calculator.
References
The codes and texts the calculator follows, consulted on 19 November 2026. Always use the edition and national annex you will actually rely on.
- ICC: International Building Code 2021: §1011.5.2 riser height and tread depth
- ICC: International Residential Code 2021: §R311.7.5 stair treads and risers
- UK Government: Approved Document K: Protection from falling, collision and impact (2013 edition incorporating 2013 amendments), Table 1.1 and §1.2–1.5
Part of our free engineering tools and design guides. Results are for preliminary design and checking, and must be verified by a qualified structural engineer responsible for the project. Clauses are referred to where we are confident of the reference; always check the edition and national annex adopted for your project.
Questions we are asked about this.
How do you calculate the number of stairs?
Divide the floor-to-floor height by the maximum riser height allowed and round up. For 3,000 mm with a 178 mm maximum that is 17 risers of 176.5 mm. The number of treads in a straight flight is one less.
What is the standard riser height?
The IBC allows 102 to 178 mm (4 to 7 in) for commercial buildings, the IRC up to 196 mm (7¾ in) for houses, and Approved Document K up to 220 mm for private stairs in the UK.
What is the 2R + G rule?
Twice the riser plus the going should be between 550 and 700 mm (Approved Document K). It keeps the step comfortable for a normal stride; around 620 to 640 mm is ideal.
What is the minimum tread depth?
279 mm (11 in) under the IBC, 254 mm (10 in) under the IRC, and 220 mm going for a UK private stair.
What is the maximum pitch of a stair?
Approved Document K limits private stairs to 42°. The IBC and IRC limits on riser and tread give at most about 32.5° and 37.8°.
How much concrete is in a stair?
The waist slab (slope length × thickness × width) plus the triangular steps (½ × riser × going × width each) plus the landings. The calculator adds them up for you.
Send the drawings. Get an answer from our engineers.
WhatsApp or email the architectural or structural set, the location and what you need. The reply comes from the engineers who will do the work, with a proposed scope and programme.
- +971 52 118 2569
- Telephone
- +971 52 118 2569
- Office
- Al Warqa 1, Dubai, UAE
- Hours
- Sunday – Thursday, 09:00 – 18:00 GST